WARNING AND SAFETY PRECAUTIONS
1. WARNING: DO NOT look directly into the UV light source as it may be damaging to your eyes.
2. WARNING: DO NOT let UV ultraviolet ray shine on exposed skin.
3. WARNING: DO NOT dismantle or immerse this product in water to avoid the occurrence of failures.
4. WARNING: DO NOT let children touch or use this product.
1. Open up magnetic zipper, place items on the metal rack.
2. Zip up completely, and let magnetic zipper slider fall naturally. Zipper slider will automatically latch onto the magnet
on the side of the sterilizer bag.
3. After plugging in the power source, press to enter into Standby Mode, then press to change among the
different modes below:
OPERATING INSTRUCTIONS
Specifications are subject to change without prior notice. If there is any inconsistency or ambiguity between the English
version and the Chinese version, the Chinese version shall prevail. Refer to www.germanpool.com for the most up-to-date
version of the Operating Instructions.
SPECIFICATION
PRODUCT STRUCTURE
Reflective Strip
ON/OFF Button
ATTENTION:
1. This product’s performance and effectiveness are subjected to disinfection time, item being disinfected and surrounding
environmental factors.
2.This product is not a medical device. We do not claim that this product can treat, heal or defend against any illness or
medical condition, or reduce its spread or severity.
Please read these instructions and warranty information
carefully before use and keep them handy for future reference.
USER MANUAL
uv
+
ozone
S T E R I L I Z E R B A G
OUB-108GY
Handle
Micro USB Interface
Zipper with Magnetic Closure
Pouch with Zipper
Trolley Sleeve
Comes with removable shoulder strap that allows the bag to be worn vertically or
horizontally. Simply snap the strap onto the rivets on the sides of the bag.
Rivets for Removable Strap
MODE
INDICATOR LIGHT
DEFAULT
OPERATION
TIME
ŔŵŢůťţźġŎŰťŦ
ňųŦŦůġōŪŨũŵġŐů
İ
ŖŗġŔŵŦųŪŭŪŻŢŵŪŰůġŎŰťŦ
ŇŭŢŴũŪůŨġňųŦŦůġōŪŨũŵġ
ĶġŮŪůŶŵŦŴ
ŐŻŰůŦġŔŵŦųŪŭŪŻŢŵŪŰůġŎŰťŦ
ŇŭŢŴũŪůŨġŃŭŶŦġōŪŨũŵ
ĶġŮŪůŶŵŦŴ
ŖŗġĬġŐŻŰůŦġŔŵŦųŪŭŪŻŢŵŪŰůġŎŰťŦ
ŇŭŢŴũŪůŨġŃŭŶŦġňųŦŦůġōŪŨũŵ
ĶġŮŪůŶŵŦŴ
Model No.
OUB-108GY
Rated Voltage
DC 5V
Rated Power
3.5 W
UV Wavelength
270 nm - 285 nm / 390 nm - 410 nm
Product Dimensions
(H)145 (W)280 (D)220 mm
Net Weight
0.86 kg
Metal Rack
UV-LED Light
Ozone Outlet
View Window
4. During sterilization process, if magnetic zipper head is detached from the magnet, or if you long-press for 2
seconds, the product immediately returns to Standby Mode.
5. After sterilization process is completed, product automatically returns to Standby Mode. If left in Standby Mode for
1 minute, the product will automatically turn off.