background image

P.7

INSTALLATION INSTRUCTIONS

 

WARNING!

The gas cooking range must be installed by registered gas installers (RGI). Otherwise, German Pool will 

not be held responsible for any damages.

Attention:

• 

The use of a gas-cooking appliance produces heat and moisture. Please ensure that the kitchen 
is well ventilated. It is recommended to keep natural ventilation windows open or install a 

mechanical ventilation device (exhaust fan or range hood). For prolonged intensive use of the 

appliance, additional ventilation is required, for example opening windows or doors, or increasing 
the level of mechanical ventilation where present.

• 

Install the built-in hob in a well ventilated room and keep it away from any combustible or 

inflammable objects such as paper or oil.

• 

Place the built-in hob on a stable and level surface.

• 

If the unit is to be installed close to combustible surroundings (such as wooden walls, wooden 
shelves), it should be installed at least 15 cm (6”) from the side walls. The unit should be installed 

with a distance of at least 15 cm away from surrounding combustible materials.

• 

Leave at least 25 mm (1”) gap between the underside of the cooking range and the countertop/

cabinet shelf board below.

• 

External gas governor is not required.

I. Room Ventilation

The kitchen should have no less than 20m³ air volume for regular gas combustion and be kept well 

ventilated at all time. Air must be able to naturally flow through the permanent opening in the walls (eg. 
windows and doors) of the room.

These openings must be able to vent the fumes outdoors and their openings must be at least 100cm², 
and ensure that they should never be blocked. Indirect ventilation by air drawn from an adjacent room 
is also permitted, in strict compliance with any local regulation in force.

II. G

as

 Ventilation

Attention:

According to the Gas Safety Regulations of Hong Kong, any gas installation works including the 

installation of appliances and connection tubing, must be undertaken by registered gas installers (RGI) 

who are registered for that appropriate classes and be employed by registered gas contractors.

Before connecting the appliance, check that the specifications on the data label affixed to the 

underside of the hob correspond to those of the gas and electricity mains in the house. A label on the 
appliance indicates the regulating conditions: Type of gas and working pressure. Gas connection must 

comply with the pertinent standards and provisions in force. The size of the gas inlet is ½ inch.

Summary of Contents for GP13 Series

Page 1: ...6 Please read these instructions and warranty information carefully before use and keep them handy for future reference Online Warranty Registration U S E R M A N U A L Built in Gas Cooking Range GP13...

Page 2: ...ontents Warnings Safety Precautions Product Structure Installation Instructions Operation Instructions Cleaning Maintenance Troubleshooting Technical Specification Warranty Terms Conditions 03 05 07 1...

Page 3: ...nstructions for use 1 The cooking range must be installed by registered gas installers 2 Ensure that the cooking range is used with good ventilation Environment with insufficient oxygen should be avoi...

Page 4: ...with glass top panel should also be noted in order to prevent the glass top panel from breaking Clean the burner assembly frequently to maintain a clear gas passage on the flame distributor Clean and...

Page 5: ...ss Panel Body Gas Inlet Joint Burner Rack Drip Pan Burner Head H Knob Battery Box bottom of unit GP13 2 TG GP13 2 LG Burner Cap Burner Ring Sparker Flame Sensor Glass Panel Body Gas Inlet Joint Burner...

Page 6: ...ass Panel Body Burner Cap Burner Ring Flame Sensor Drip Pan Glass Panel Body Gas Inlet Joint Burner Rack Drip Pan Burner Head H Knob Battery Box bottom of unit Gas Inlet Joint Burner Rack Sparker Burn...

Page 7: ...king range and the countertop cabinet shelf board below External gas governor is not required I Room Ventilation The kitchen should have no less than 20m air volume for regular gas combustion and be k...

Page 8: ...necting from inch B S P thread at back of the unit to the gas supply point Stainless steel braided flexible hose connection please use approved stainless steel braided flexible tubing bearing EMSD app...

Page 9: ...head to deform or the glass may break or increase the risk of releasing carbon monoxide CO Burner Ring Burner Cap Burner Head Base Gap Burner Head Base Fig 2 Fig 3 IV Correct Position of Burner Rack...

Page 10: ...seconds 2 If the flame goes out when you release your hand repeat the ignition procedure again but try releasing your hand slowly 3 Turn Control Knob to adjust flame to desirable setting 4 Turn the C...

Page 11: ...too low Ports of burner cap are clogged Air hole is not properly adjusted Open gas valve or change gas supply Prolong ignition time and repeatedly ignite till air is vented out Straighten gas hose Co...

Page 12: ...as 1500 Pa L 6 0kW R 6 0kW DC 1 5V x 1 Impulse Ignition System Yes 125 H x 750 W x 450 D 15 kg H K LP Gas 2900 Pa L 5 0kW R 5 0kW Model GP13 2M TG GP13 2M LG Gas Type Gas Working Pressure Rated Heat I...

Page 13: ...P 13 14 15 17 20 21 21 22 23...

Page 14: ...P 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 34cm 10...

Page 15: ...P 15 GP13 3 TG GP13 3 LG GP13 2 TG GP13 2 LG...

Page 16: ...P 16 GP13 2M TG GP13 2M LG GP13 1 TG GP13 1 LG...

Page 17: ...P 17 15 6 15 25 1 I 20m 100c II A EMSD APPROVAL GTXXXX EMSD APPROVAL GTXXXX B S P B EMSD APPROVAL GTXXXX B S P...

Page 18: ...P 18 III R GP13 3 TG GP13 3 LG GP13 2 TG GP13 2 LG GP13 2M TG GP13 2M LG GP13 1 TG GP13 1 LG 815 665 463 265 405 345 342 490 50 50 D W R...

Page 19: ...P 19 1 2 3 B 2 3 IV A 1...

Page 20: ...P 20 4 5 1 6 8 2 3 4 4 5 6 5...

Page 21: ...P 21 1 5 x1...

Page 22: ...5 0kW 1 6kW 5 0kW GP13 2 TG GP13 2 LG 1500 Pa 6 0kW 6 0kW DC 1 5V x 1 125 x 750 x 450 15 kg 2900 Pa 5 0kW 5 0kW GP13 2M TG GP13 2M LG 1500 Pa 6 0kW 1 6kW DC 1 5V x 1 125 x 580 x 380 10 8 kg 2900 Pa 5...

Page 23: ...part 5 This warranty will be void if there is any transfer of ownership from the original purchaser 1 2 3 4 5 Serial No Purchased From Invoice No Purchase Date Model No Please fill out the form below...

Page 24: ...9 6809 8th Xinxiang Road Wusha Industrial Park Daliang Shunde Foshan Guangdong 3 F Edificio Industrial Pou Fung 145 Rua de Francisco Xavier Pereira Macau Tel 853 2875 2699 Fax 853 2875 2661 Macau All...

Reviews: