P.7
INSTALLATION INSTRUCTIONS
WARNING!
The gas cooking range must be installed by registered gas installers (RGI). Otherwise, German Pool will
not be held responsible for any damages.
Attention:
•
The use of a gas-cooking appliance produces heat and moisture. Please ensure that the kitchen
is well ventilated. It is recommended to keep natural ventilation windows open or install a
mechanical ventilation device (exhaust fan or range hood). For prolonged intensive use of the
appliance, additional ventilation is required, for example opening windows or doors, or increasing
the level of mechanical ventilation where present.
•
Install the built-in hob in a well ventilated room and keep it away from any combustible or
inflammable objects such as paper or oil.
•
Place the built-in hob on a stable and level surface.
•
If the unit is to be installed close to combustible surroundings (such as wooden walls, wooden
shelves), it should be installed at least 15 cm (6”) from the side walls. The unit should be installed
with a distance of at least 15 cm away from surrounding combustible materials.
•
Leave at least 25 mm (1”) gap between the underside of the cooking range and the countertop/
cabinet shelf board below.
•
External gas governor is not required.
I. Room Ventilation
The kitchen should have no less than 20m³ air volume for regular gas combustion and be kept well
ventilated at all time. Air must be able to naturally flow through the permanent opening in the walls (eg.
windows and doors) of the room.
These openings must be able to vent the fumes outdoors and their openings must be at least 100cm²,
and ensure that they should never be blocked. Indirect ventilation by air drawn from an adjacent room
is also permitted, in strict compliance with any local regulation in force.
II. G
as
Ventilation
Attention:
According to the Gas Safety Regulations of Hong Kong, any gas installation works including the
installation of appliances and connection tubing, must be undertaken by registered gas installers (RGI)
who are registered for that appropriate classes and be employed by registered gas contractors.
Before connecting the appliance, check that the specifications on the data label affixed to the
underside of the hob correspond to those of the gas and electricity mains in the house. A label on the
appliance indicates the regulating conditions: Type of gas and working pressure. Gas connection must
comply with the pertinent standards and provisions in force. The size of the gas inlet is ½ inch.
Summary of Contents for GP13 Series
Page 13: ...P 13 14 15 17 20 21 21 22 23...
Page 14: ...P 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 34cm 10...
Page 15: ...P 15 GP13 3 TG GP13 3 LG GP13 2 TG GP13 2 LG...
Page 16: ...P 16 GP13 2M TG GP13 2M LG GP13 1 TG GP13 1 LG...
Page 19: ...P 19 1 2 3 B 2 3 IV A 1...
Page 20: ...P 20 4 5 1 6 8 2 3 4 4 5 6 5...
Page 21: ...P 21 1 5 x1...