Function
Value
Remark
ADJU CODE
xxxx
Adjustments in the internal setup are code protec-
ted (for authorized persons only).
CL1C
- 99 - + 99
Coarse adjustment of the Color wheel 1
CL1F
- 99 - + 99
Fine adjustment of the Color wheel 1
CL2C
- 99 - + 99
Coarse adjustment of the Color wheel 2
CL2F
- 99 - + 99
Fine adjustment of the Color wheel 2
GOB1
- 99 - + 99
Adjustment of Gobo wheel 1
GOB2
- 99 - + 99
Adjustment of Gobo wheel 2
GOB3
- 99 - + 99
Adjustment of Gobo wheel 3
SHSH
- 99 - + 99
Shutter moves pair wise open and close
SHOC
- 99 - + 99
Shutter moves pair wise parallel left and right
FR U
- 99 - + 99
Adjustment of the Frost filter A
FR O
- 99 - + 99
Adjustment of the Frost filter B
PRIS
- 99 - + 99
Adjustment of the Prism wheel
IRIS
- 99 - + 99
Adjustment of the Iris
FOCU
- 99 - + 99
Adjustment of the Focus
POFS
- 99 - + 99
Adjustment of the Pan-Offsets
TOFS
- 99 - + 99
Adjustment of the Tilt-Offsets
CLRE
Adjustments in the internal circuit.
SPFS
- 99 - + 99
Speed fast - limits max. PAN speed to 70%
ARES
- 99 - + 99
Adjust Reset (wheels stand still after the reset)
3.9.9 Default
Settings
(DFSE)
DFSE
Press
Enter
to reset all fixture personalities (not the adjusted/calibrated
functions) to the factory default values. On the display
ok
will appear to
indicate that the defaults are now set.
Function
Display
Default Settings
DMX Address
D001
D001
Pan reverse
RPAN
ON
OFF
9
Tilt reverse
RTLT
ON
OFF
9
Automatic lamp on
LAAU
ON
OFF
9
Lamp on via DMX
DLOF
ON
9
OFF
Display
DISP
D ON
9
REV
Cooling fan
FANS
HIGH REG
9
LOOF LOHI
Feedback
FEED
ON
9
OFF
3.9.10 Automatic position control / Feedback
(FEED)
FEED
The
Y
Y
P
P
O
O
C
C
7
7
0
0
0
0
is equipped with a automatic position correction (feedback)