background image

 
 

 

 

Accessing the Armed Mode of GV-AS Controllers

 

 

Article ID: GV4-17-10-31-al 

Release Date: 10/31/2017 

Revised Date: 04/27/2018 

 

Applied to 

GV-AS210 / 2110 / 2120 Firmware V2.11 or later 

GV-AS410 / 4110 / 4111 Firmware V2.11 or later 

GV-AS810 / 8110 / 8111 Firmware V2.11 or later 

GV-ASManager V5.0.1.0 or later 

GV-RK1352 Reader 

 

Note:

 This document is dedicated to Texecom Intruder Alarm System.

 

 

Contents 

1.  Enabling the Armed Mode............................................................................................... 3 

1.1    Defining the Output function

........................................................................................... 3 

1.2    Defining the Input function

.............................................................................................. 4 

1.3  Adding a Security Card

.................................................................................................. 5 

2.  Disabling the Armed Mode .............................................................................................. 8 

 

Summary of Contents for GV-AS210

Page 1: ...later GV AS410 4110 4111 Firmware V2 11 or later GV AS810 8110 8111 Firmware V2 11 or later GV ASManager V5 0 1 0 or later GV RK1352 Reader Note This document is dedicated to Texecom Intruder Alarm S...

Page 2: ...the Armed Mode you need to define the output and input functions of a GV AS21 41 81 series Controller and add a Security Card on GV ASManager After the setup is complete present a security card and th...

Page 3: ...interface click Output Configuration to define the output function Output Type Output Function 1 2 3 2 Set the Output Type to Door associated with this output 3 Select Alarm Keyswitch as the Output f...

Page 4: ...guration to define the input function 5 Set the Input Type to be the same as the Output Type in Step 2 6 Select Armed status as the input function The controller door will enter the Armed Mode where n...

Page 5: ...k with the Armed Mode click the Door tab of the Controller Setup dialog box B Click Authentication Schedule and specify the access mode to either Card Mode or Card or Common Mode at different periods...

Page 6: ...our digit PIN code for the card D Assign the security card to an access group using the Access Group drop down list For details see 4 5 Setting Access Groups in the GV ASManager User s Manual 8 To ena...

Page 7: ...blue standby mode After connecting the control wires of the reader s LEDs to the outputs on GV AS Controller i Enable the external controls of LED on GV R RK DFR Config AP ii Go to the Output Configu...

Page 8: ...or any reason the intruder alarm system is not responding correctly you can temporarily disable the Armed Mode Present the security card to the reader followed by entering the PIN code five times cons...