Section 1: System Description 

 

Function and Theory 

 
The Geotech Product Recovery Canister (PRC) is a passive, skimmer device designed to 
recover light floating hydrocarbons (such as gasoline and diesel fuel) from the ground 
w

ater in wells that are 2” (5cm) and larger. 

 
Featuring a floating oleophilic/hydrophobic intake assembly, the skimmer can 
automatically collect and skim floating product down to a sheen. 

Standard  2” skimmers 

provide 12” (30cm) of intake travel and standard 4” skimmers provide up to 16” (40cm) of 
intake travel, to accommodate water fluctuations. The unit is suspended in the well at the 
desired recovery depth by supplied stainless steel suspension cable. 

System Components 

 
A PRC consists of two (2) major components; a product skimmer assembly and a 
collection canister (as shown in Figures 1-1 through 1-3). 

On the 4” model, the skimmer 

assembly is protected by a slotted screen that pre-filters the incoming product and 
protects the intake assembly from damage. The skimmer assembly collects free product 
and passes it through a coiled hose to the collection canister. Recovered product is 
evacuated by removing the PRC from the well and opening the drain on the bottom of the 
device. 
 
Increased capacity collection canisters are available and easily installed by simply 
unscrewing the collection canister section and replacing it with a larger collection canister 
and weight assembly. When going from smaller to larger collection canisters, 
consideration must be made for weight. Going from larger to smaller is not a problem. 

Summary of Contents for PRC

Page 1: ...Rev 10 27 2020 Part 26650319 Product Recovery Canister Installation and Operation Manual...

Page 2: ......

Page 3: ...and Theory 3 System Components 3 Section 2 System Installation and Operation 4 Section 3 System Maintenance 6 Section 4 System Troubleshooting 7 Section 5 System Specifications 9 Section 6 System Sche...

Page 4: ...ceed until you read and thoroughly understand the WARNING message WARNING CAUTION A raised hand icon indicates CAUTION information that relates to a situation or condition that could lead to equipment...

Page 5: ...System Components A PRC consists of two 2 major components a product skimmer assembly and a collection canister as shown in Figures 1 1 through 1 3 On the 4 model the skimmer assembly is protected by...

Page 6: ...4 Figure 1 1 2 PRC Skimmer Assembly Figure 1 2 4 PRC Skimmer Assembly 1 liter Figure 1 3 4 PRC Skimmer Assembly 3 liter...

Page 7: ...nt To empty the collection canister simply pull the PRC up from the well open the drain valve by applying a downward pulling force on the valve sleeve like a water bottle and transfer the recovered pr...

Page 8: ...bstructions such as kinks Replace the tubing coil as necessary 3 Inspect the collection canister for physical damage such as cracks Replace as necessary 4 To clean the intake assembly screen intake us...

Page 9: ...em The drain valve is not fully closed Solution Empty the collection canister as described in Section 2 System Installation and Operation and then close the drain valve by pushing up on the outer slee...

Page 10: ...scribed in Section 2 System Installation and Operation Problem The canister vent is blocked Solution Make sure that the holes in the suspension fitting are clear of debris The PRC will not operate if...

Page 11: ...OD 4 8cm 1 82 5 L 210cm x 1 88 OD 4 8cm 4 1 37 L 94cm x 3 5 OD 9cm 3 53 0 L 135cm x 3 5 OD 9cm 4 60 0 L 152cm x 3 5 OD 9cm Weight Size Volume L Empty Weight Full Weight 2 0 125 2 9lbs 1 3kg 3 1lbs 1 4...

Page 12: ...ume L Capacity gallons 2 0 125 0 035 0 25 0 07 0 5 0 13 1 0 26 4 1 0 26 3 0 8 4 1 06 Minimum Water Required Size Volume L Depth 2 0 125 23 5 60cm 0 25 29 0 74cm 0 5 39 5 100cm 1 62 0 157cm 4 1 18 5 47...

Page 13: ...11 Section 6 System Schematic Figure 6 1 PRC Skimmer deployed in well...

Page 14: ...12 Section 7 Replacement Parts List Figure 7 1 Standard 2 PRC Skimmer Assembly...

Page 15: ...50304 11 CAP PVC TOP PRC2 26650315 12 BODY PVC CANISTER 0 125L PRC 26650321 BODY PVC CANISTER 0 25L PRC 26650307 BODY PVC CANISTER 0 5L PRC 26650311 BODY PVC CANISTER 1LITER PRC 26650313 13 ASSY WEIGH...

Page 16: ...14 Figure 7 2 Standard 4 PRC Skimmer Assembly 1 Liter...

Page 17: ...UPLER PVC PRC4 16650316 8 SCREEN PVC PRC4 16650317 9 HOSEBARB BRS 170 X1 8MPT 90D 17500148 10 CANISTER 1L PRC4 W BTM PLATE 56650311 11 CLAMP SS STEPLESS EAR 7MM 16600005 12 CLAMP SS6 CABLE LOW PRFL 16...

Page 18: ...16 Figure 7 3 Standard 4 PRC Skimmer Assembly 3 4 Liter...

Page 19: ...CANISTER PVC 4L PRC4 16650320 10 WEIGHT SS4 3L 4L PRC4 16650319 11 CLAMP SS STEPLESS EAR 7MM 16600005 12 HOSEBARB BRS 170 X1 8MPT 90D 3 LITER 17500148 HOSEBARB BRS 1 8 X1 8 NPT 4 LITER 16600065 13 O...

Page 20: ...0125 specs to system specifications added revision history StellaR 6 27 2018 1670 Corrected table title in Section 5 System specifications Corrected weight for 125 volume StellaR 6 29 2018 2093 Added...

Page 21: ...19 NOTES...

Page 22: ...20 NOTES...

Page 23: ...al Authorization number RMA is required prior to return of any equipment to our facilities please call our 800 number for appropriate location An RMA will be issued upon receipt of your request to ret...

Page 24: ...Geotech Environmental Equipment Inc 2650 East 40th Avenue Denver Colorado 80205 303 320 4764 800 833 7958 FAX 303 322 7242 email sales geotechenv com website www geotechenv com...