background image

 

 Page 18 of 18 

Operating Manual 

www.geotechuk.com

 

LFWATOM01  Iss.12 

© QED Environmental Systems Ltd. 

 

A TE X

 

D I PM E TE R

 

WEEE COMPLIANCE 

The wheelie bin symbol displayed on equipment supplied by QED Environmental Systems Limited signifies that 
the apparatus must not be disposed of through the normal municipal waste stream but through a registered 
recycling scheme.  

The Waste Electrical and Electronic Equipment directive (WEEE) makes producers responsible from July 1

st

 2007 

in meeting their obligations, with the fundamental aim of reducing the environmental impact of electrical and 
electronic equipment at the end of its life. 

QED is now registered with the Environmental Agency as a producer and has joined a recycling scheme provider 
who will manage and report on our electrical waste on the company’s behalf.   

When 

your instrument is at the end of its life, please contact the QED sales team who will advise you on the next 

step in order to help us meet our WEEE obligations. 

 

  

Summary of Contents for Atex Dipmeter

Page 1: ...ATEXDIPMETER OPERATING MANUAL...

Page 2: ...und when the unit is tested 7 Continuous Sound when the unit is turned on or probe removed from water 7 To test the system 7 General 8 EU Declaration of Conformity 9 Appendices safety instructions 10...

Page 3: ...ow to troubleshoot the meter in case you have any issues and includes the declaration of conformity Hazard warnings and safety symbols Information in this manual that may affect the safety of users an...

Page 4: ...e of practice IEC 60079 19 If the equipment is likely to come into contact with aggressive substances then it is the responsibility of the user to take suitable precautions that prevent it from being...

Page 5: ...NT REAR FRONT FASCIA A Battery compartment H Date time stamp of manufacture B Probe I On Off switch C Instrument test function J Increase sensitivity button D Maximum depth K Decrease sensitivity butt...

Page 6: ...he buzzer and light should activate if not adjust the sensitivity and repeat Make sure the unit is on Test the unit in tap water before going out to the field DO NOT use distilled or de ionised water...

Page 7: ...yl and 1 3 denatured alcohols freons TF TE Rinse well with water and let it dry before putting the panel back in Do NOT use abrasives partially halogenated hydrocarbons or ketones to clean the reel If...

Page 8: ...ATEX DIPMETER General Avoid sharp edged casing Avoid entanglement with other equipment in boreholes and wells Do not use as guide to backfilling with sand etc Instrument may get locked in sand Rewind...

Page 9: ...Page 9 of 18 Operating Manual www geotechuk com LFWATOM01 Iss 12 QED Environmental Systems Ltd ATEX DIPMETER EU DECLARATION OF CONFORMITY...

Page 10: ...e est certifi comme tant adapt l installation en zone dangereuse II 2 G Ex ia IIB T4 Gb Cet appareil est certifi pour utilisation temp rature ambiante comprise entre 20 et 40 C mais la sonde peut tre...

Page 11: ...infiltration d eau Test du syst me Maintenir la goupille centrale de la sonde contre le goujon au dos de l axe de bobine et en m me temps toucher la vis du cadre l aide de la sonde Si le syst me fonct...

Page 12: ...dass das Ger t in Kontakt mit aggressiven Substanzen kommt liegt es in der Verantwortung des Benutzers geeignete Vorsichtsma nahmen zu treffen die negative Auswirkungen auf das Ger t verhindern und s...

Page 13: ...geschaltet oder Sonde aus dem Wasser entfernt wird berpr fen dass die Spitze des Sondenleiters sauber ist Auf berm ige Feuchtigkeit an der R ckseite des Elektronikfelds pr fen Sonden Bandverbindung un...

Page 14: ...zate non vengano danneggiate Il misuratore di profondit stato certificato in base alla classificazione delle aree pericolose II 2 G Ex ia IIB T4 Gb Questa apparecchiatura certificata unicamente per l...

Page 15: ...otture e perdite che potrebbero provocare l ingresso di acqua Per povare il sistema Tenere il perno centrale della sonda contro il montante sul retro dell asse della bobina e toccare contemporaneament...

Page 16: ...garantizar que no se comprometa el tipo de protecci n El dipmeter ha sido homologado en la clasificaci n de zonas peligrosas como II 2 G Ex ia IIB T4 Gb El equipo s lo est homologado para utilizarse a...

Page 17: ...rar agua Para probar el sistema Sostenga el borne central de la sonda contra el esp rrago de la parte trasera del eje del carrete y a la vez toque el tornillo en el bastidor con el cuerpo de la sonda...

Page 18: ...ectronic Equipment directive WEEE makes producers responsible from July 1st 2007 in meeting their obligations with the fundamental aim of reducing the environmental impact of electrical and electronic...

Reviews: