Installer manual NETZERO
GEOSMART ENERGY
26
EN
2.6.
Configuration of the DHW production service
DHW
1.
Used to enable the DHW production service.
2.
Used to enable use of the circulator pump for the DHW service.
3.
Use to enable the use of a DHW recirculation pump.
DHW cascade
1.
Allows enable the independent DHW production on each heat pump that is connected
in parallel.
Note:
Enable this configuration, in a heat pump connected in parallel, means that the heat
pump manages its aunt tank and not one common for the installation.
DHW tank
1.
Allows adjust the maximum settable DHW tank setpoint. This is the setpoint in case of
surplus for the SG states.
2.
Used to adjust the setpoint temperature in the DHW storage tank for the legionella
protection program. Allows adjust the minimum settable cooling buffer setpoint. This
is setpoint in case of surplus for the SG states.
2.7.
Configuration of the pool service
Pool
1.
Used to enable the pool service.
2.
Used to adjust the target outlet temperature in pool mode. Also used to set the request
logic of the pool.
3.
Used to enable use of the production circulator pump for the pool service.
Connection type
1.
Used to select whether the pool is connected in parallel to the heating circuit or the
DHW circuit (HTR system).
Special parameters
1.
Used to adjust the target temperature difference between the production circuit
outlet and inlet in pool mode.
Pool
1.
Allows adjust the maximum settable pool setpoint. This is the setpoint in case of
surplus for the SG states.
Installer menu
2/7
a.Change language
b.Configuration
c.Information
Configuration
3/7
b.Sources
c.Services setup
d.Auxiliary systems
Services setup
3/6
b.Cooling
c.DHW
d.Pool
DHW
Enable:
Production pump:
Recirculing pump:
DHW cascade
Independent use,
enable:
DHW Tank
Max SetP.:
65 ºC
Legionella
SetpointT:
65 ºC
Installer menu
2/7
a.Change language
b.Configuration
c.Information
Configuration
3/7
b.Sources
c.Services setup
d.Auxiliary systems
Services setup
4/5
c.DHW
d.Pool
e.Priorities
Pool
Enable:
DI4 logic:
NA
Tsupply:
10.0ºC
Connection type
Special parameters
DTpool:
5.0ºC
Pool
Max SetP:
30 ºC