GeoSIG GeoSwitch Quick User Manual Download Page 1

Connections 

The GeoSwitch has 16 screw terminals which allow for connection of power, serial 
connection, clear switch and three relays. 

Connector 

Pin 

Name

 

Comment

 

J2

01

 

+9-28 VDC 

Power line for external power supply 

GND 

Ground line for external power supply 

TXD/A 

TXD line of RS232 interface or A line of 
RS485 interface (MODBUS) 

RXD/B 

RXD line of RS232 interface or B line of 
RS485 interface (MODBUS) 

GND 

Ground line for RS232 or RS485 interface 
(MODBUS) 

CLR_SW 

Clear Switch input 

GND 

Ground line for Clear Switch input 

K1_NC 

Normally closed contact of relay 1 

K1_CMN 

Common contact of relay 1 

10 

K1_NO 

Normally opened contact of relay 1 

11 

K2_NC 

Normally closed contact of relay 2 

12 

K2_CMN 

Common contact of relay 2 

13 

K2_NO 

Normally opened contact of relay 2 

14 

K3_NC 

Normally closed contact of relay 3 

15 

K3_CMN 

Common contact of relay 3 

16 

K3_NO 

Normally opened contact of relay 3 

 

 

For the pin colour code of the supplied GeoSwitch cable please refer to Appendix D and 
E in the user manual or check the GeoSwitch Cable drawing supplied with the product. 

 

Further reading 

For further reading on operation and correct use of the instrument, please refer to the user 
manual and datasheet which are available from the GeoSIG Ltd website: www.geosig.com 

 

 

 

 

 

 

 

GeoSwitch Quick User Manual 

 

 

 

 

 

 

 

V3 

GeoSIG Ltd, Wiesenstrasse 39, 8952 Schlieren, Switzerland 

Phone: + 41 44 810 2150,  Fax: + 41 44 810 2350 

[email protected],  www.geosig.com 

 

Reviews: