LX-80-15 10 Hz User Manual
15
LX-80-15 10 Hz Oceanographic Radar Sensor
6
Radar Settings
To change the radar settings, connect the level meter to the PC computer, and start the Geolux
Instrument Configurator PC application. Through the user interface of the application, the following
parameters can be configured.
Communication Interfaces Parameters
Baud rate
1
0
0
1
0
0
1
0
1
1
0
1
N bits per second
Band Rate
1 bit
RS-232 baud rate
- Configures the baud rate (bits per second) for serial communication on RS-232
data line. This setting controls how many bits are sent on the communication line in one second. The
available values are standardised. Using higher baud rates over longer lines may introduce errors in
transferred data. The default instrument RS-232 baud rate is 115200 bps.
RS-485 baud rate
- Configures the baud rate (bits per second) for serial communication on RS-485
data line. This setting controls how many bits are sent on the communication line in one second. The
available values are standardised. Using higher baud rates over longer lines may introduce errors in
transferred data. The default instrument RS-485 baud rate is 9600 bps.
RS-232 settings
Configures which parts of NMEA output is available over the interface. This setting is available on
devices with firmware versions above 2.3.9. By default the flags parameter is 0, which enables all
NMEA sentences. This parameter can be any of the following values:
0 - All NMEA sentences are sent over the interface
2 - $ANG NMEA sentence is not sent over the interface
Device ID
ID
ID+1
ID
Device ID
Summary of Contents for LX-80-15
Page 62: ...2022 ...