Geokon GK-406 Quick Start Manual Download Page 1

GK-406-MUX - VW ANALYZER LOAD CELL MULTIPLEXER 

 |  QUICK START GUIDE

Document Revision: A | Release date: 03/9/22

GK-406-MUX

VW Analyzer Load cell multiplexer - Quick Start Guide

SETUP

1.

Remove the protective silicon cover from the multiplexer and install the AA alkaline batteries (2) into the rear battery 
compartment.

2.

Install the multiplexer back into the protective silicon cover.

3.

Connect the VW Analyzer to the multiplexer using the supplied cable.

4.

Connect the load cell to the multiplexer.

OPERATION (USING THE VW ANALYZER)

1.

Press the power button just under the left side of the readout screen on the VW Analyzer.

2.

Select or add a user and the home screen is displayed.

3.

Select 

Read & Record

 and then 

Site/Sensor 

to get a load cell reading.

4.

Select the load cell location or add a new location. There is an option add a default sensor to the new location.

5.

Select 

Next

 and then select the specific load cell model to be used or add the information as a new sensor.

6.

Select 

Read

 and the readout screen is displayed.

7.

Select 

Details 

in the readout screen to show more data. Select 

Gauge

 from the details screen

 

to toggle between the average 

of all the vibrating wire sensors measurements in the load cell and the individual measurements of each sensor. Spectrum 
and Time graphs are also available from the 

Details

 screen.

1: 

1

Single 10-pin connector for load cell connection

2

Low battery indicator

3

2m VW Analyzer connector cable (included)

Power: (2) AA alkaline batteries (included)

2m VW Analyzer connector cable (included)

IP-40 rated case with silicone protective cover

Multiplexes all Geokon 3, 4 and 6 gauge VW load cells to use 
the GK-406 VW Analyzer

 

1

 

2

 

3