Troubleshooting (cont.)

Q. I press the keys on the keypad, and there is no sound or response from

the controller.

A. Check the connection of the keypad to the controller. This is inside

the top panel. Unplug the power cord. Remove the two screws in
between the clamp/linkage that hold down the top panel, and carefully
lift the panel up and look inside at the digital controller. The keypad
connector passes in through the top panel. It should wind around the
first circuit board and be seated fully into the connector. Check the
black keypad connector that plugs into the circuit board to see if it has
pulled apart. Also check the area where the keypad connects to the
front membrane to see if the leads have been damaged. The membrane
keypad may need to be replaced.

Q. The press will not activate.
A. Check the air connection to the press. Make sure the compressor

supplying the air is on, and no relief valves have opened on the
compressor. Check the air gauge, it should be set to a reading of 20-
80 psi. Check to make sure the limit micro-switch in the back of the
press is closing when the head is swung over. If the head is not swung
all the way over the table, and the rear limit micro-switch is not being
closed, the press will not activate. If all of these check points have
been tried, and the digital control is counting down, but the press is
not pressing, contact Geo Knight technical support. If the Digital
Controller is not counting down when attempting to activate, one or
both of the black activation switches needs replacement.

Q. The press has shut off, and will not come back on after checking the

power cord, on/off switch, etc.

A. Check the fuse. In the back panel of the control box, the power cord

socket has a built-in fuse-holder. Unplug the power cord, and gently
pry out the fuse-holder. If the fuse is burnt out or there is no continuity,
replace it. If the fuse is fine, check the black and white wire connections
from the power socket to the on/off switch, and from the on/off switch
to the controller inside the head.

Q. I pressed a transfer upside down. The inks and transfer material have

burned onto the heat platen.

A. Cool the press down. Using a nonabrasive detergent or cleaner, thoroughly

scrub the heat platen surface. Do not use an abrasive scrubber, or a pad
that will scratch the Teflon coating of the platen. If you are still unable to
remove the transfer material, obtain teflon heater block cleaner from the
contact information located at the end of this manual.

Summary of Contents for Digital Knight DK20SP

Page 1: ...1 Digital Knight 16x20 Automatic Digital Swinger...

Page 2: ...laten Height 6 Actuating the Press 6 Guidelines Standard Settings 7 Programmable Presets 8 User Options Menu 9 Fahrenheit Celsius 9 Timer Counter 9 Recorded Pressings 9 Pressure Height Gauge Settings...

Page 3: ...much time and effort in using this press and in your heat pressing applications Throughout this manual many areas and components of this machine will be referred to by specific names Please refer to t...

Page 4: ...s editable in the default operating mode of the controller The left two digits of the time display are minutes The right two digits are seconds This can be changed to Hours Minutes in the User Options...

Page 5: ...ange of the controller is from 150 F to 550 F 65 C to 288 C During the first heat up cycle of the press the controller will display 150 F 65 C until the heat platen temperature rises above that temper...

Page 6: ...r the heat platen turn the pressure knob to the right clockwise The top head will lower toward the pressing table Actuating the Press To actuate the machine simply press both black buttons together Th...

Page 7: ...reduce the life of the silicone pad When pressing rigid substrates plastics metals woods etc be sure that any protective films or laminates are removed before heating Always check that the transfer i...

Page 8: ...based on the best results for every application When those presets are selected the user is immediately returned to the proper settings without time consuming experimentation and risk of unsuccessful...

Page 9: ...renheit Celsius The Current Set Point and Preset temperature values can be displayed in Fahrenheit or Celsius To change the value to F or C use the arrow keys Press PRG to move to the next menu item T...

Page 10: ...results of the transfer begin to deteriorate the Drop Sense feature can help the user avoid this Use the arrow keys to set the degrees or to turn this feature off If the Current temperature drops belo...

Page 11: ...ing cycle as well as if the Drop Sense feature is enabled Use the arrow keys to change the values or to turn the alarm off Please note the different alarms below denotes a short beep _ denotes a longe...

Page 12: ...he silver colored ring around the post that stops the head from continually swinging over the table It can be loosened and retightened when the correct position is obtained Q The control displays Err...

Page 13: ...the way over the table and the rear limit micro switch is not being closed the press will not activate If all of these check points have been tried and the digital control is counting down but the pr...

Page 14: ...on site component replacement is deemed not possible by Geo Knight Co A return authorization must be granted by Geo Knight Co prior to its return If a press covered by the one year limited warranty mu...

Page 15: ...15...

Page 16: ...16...

Reviews: