Genquip Gi3300ER Owner'S Manual Download Page 1

GENQUIP GI3300ER DSP INVERTER GENERATOR 

PAGE 1

page 1

Genquip Gi3300 DSP Inverter Generator

Genquip Gi3300ER DSP Inverter Generator

Owner’s Manual

Summary of Contents for Gi3300ER

Page 1: ...GENQUIP GI3300ER DSP INVERTER GENERATOR PAGE 1 page 1 Genquip Gi3300 DSP Inverter Generator Genquip Gi3300ER DSP Inverter Generator Owner s Manual...

Page 2: ......

Page 3: ...erload indicator Charging Batteries Battery Periodic Maintenance 11 Spark Plug Inspection Oil Replacement 12 Engine Oil Replacement 13 Fuel Filter 14 Fuel Tank Filter 14 Air Filter Maintenance 14 Valv...

Page 4: ...uel Cap and Vent 4 Fuel On and Off Switch 5 AC Ready Pilot Light 6 Oil Warming Light 7 Ground Earth Terminal 8 240 Volt Sockets 9 Engine On and Off Switch 10 Recoil Stater 11 Transport Handle 12 12V D...

Page 5: ...Level Gauge To refuel remove cap and fuel slowly until fuel gauge indicates full Apply fuel cap WARNING Fuel is high flammable and poisonous DO NOT fill above the top of fuel filler or it may overflow...

Page 6: ...warning light flickers for a few seconds the engine oil is low Add oil and restart Engine Switch The engine switch controls the ignition system A Ignition circuit is switched on The engine can be star...

Page 7: ...7 page 7 Genquip Gi3300 DSP Inverter Generator Operation Starting The Engine Note Before starting the engine do not connect any electric devices 1 Turn the fuel switch lever to the ON position 2 Turn...

Page 8: ...e engine remotely push unlock button on the remote If the first attempt fails push the unlock button again 4 To shut off the generator push the lock button on the remote 5 If the generator will not be...

Page 9: ...hort term peak load is 3 300 watts and the max operating load is 3 000 watts High temperatures or high elevations will reduce the expected performance of this generator NOTE The generator s AC output...

Page 10: ...the negative terminal 4 Close the front access door panel To charge the battery Have your Genquip dealer or an qualified electrician charge the battery as soon as possible if it seems to have discharg...

Page 11: ...ce Clean Spark Arrester Screen Recoil Starter Check operation Choke Handle Check operation Fuel System Check hose condition look for leaks Fittings Fasteners Check and tighten Cooling System Air Check...

Page 12: ...Replacement You should periodically remove and inspect the spark plug 1 Check for discoloration and remove the carbon 2 Check the spark plug type and gap Standard electrode color tan colour Standard S...

Page 13: ...emove the oil filler cap so that the oil can be completely drained 5 Check the drain bolt gasket oil filler gap and O ring 6 Reinstall the oil drain bolt drain bolt torque 12 Ft lbs 7 Add engine oil t...

Page 14: ...Filter 1 Remove the fuel tank cap and filter 2 Clean the filter with solvent If damaged replace 3 Wipe the filter and insert it Be sure the tank cap is securely tightened Air Filter Maintenance 1 Rem...

Page 15: ...n the spark plug hole measure the depth 3 Insert a feeler gauge into the gap between rocker and valve to measure the valve clearance Valve Clearance Intake 0 1mm 0 004 in Exhaust 0 1mm 0 004in 4 If ad...

Page 16: ...r to cool down before refueling Always refuel the generator in a well ventilated area Keep all flammable materials and fuel away from the operating generator Always locate your generator where its exh...

Page 17: ...y Do not over fill fuel tank If fuel spillage has occurred during refueling clean the spillage completely and allow sufficient time for any fuel vapors to dissipate Tampering with the factory preset e...

Page 18: ...ation can cause Electrocution 1 Never operate the generator whilst wet or expose to damp conditions Clean the generator only when shut down and cooled down completely Do not spray water directly on or...

Page 19: ...uel shut tap is on Always use fresh fuel Check the engine switch is in the ON position Check the choke is in the open position Return choke to the closed position once running petrol model only Shutdo...

Page 20: ...running until it stops This will burn any remaining fuel in the carburettor Engine 1 Remove the spark plug Pour about one tablespoon of SAE 10W30 or 20W40 motor oil into the spark plug hole and reinst...

Page 21: ...attach spark plug lead Unit may be flooded Leave the generator to rest for 5 10 minutes and then try again following the instructions when doing so Alternatively if the choke lever is in full choke po...

Page 22: ...cables could result in crossed polarity Only use the supplied DC cables with the generator Mixed polarity Check the DC cables are connected to the correct battery polarity terminals That is positive t...

Page 23: ...e switch to the ON position Generator air filter may need cleaning Remove the air filter Check that the air filter is clean If required clean dry and re install the air filter Generator fuel filter ma...

Page 24: ...hite Blue 1 Main coil 2 Sub coil 3 Control unit 4 AC indicator light Overload indicator light 5 AC receptacle 6 Ground Earth terminal 7 Economy Control Switch 8 Step Motor controller 9 Engine switch 1...

Page 25: ...watts MAX OUTPUT 3300 watts FULL TANK OUTPUT 13500 watts RUN TIME AT 1 2 RATED LOAD 8 5 hours RUN TIME AT RATED LOAD 4 5 hours POWER CONVERSION RATE 85 92 RATED VOLTAGE 240V RATED FREQUENCY 50Hz RATED...

Page 26: ...caused by not operating or maintaining the generator according to the Owner s Manual and or Risk Assessment report 2 Damage to engine caused by operating engine with no oil insufficient oil incorrect...

Page 27: ......

Page 28: ...www genquip com au Genquip Warehouse 45 Riverside Road Chipping Norton NSW Call 1300 730 716...