Genquip Gi3300 DSP Inverter Generator
Owners Manual
Page 1: ...page 1 Genquip Gi3300 DSP Inverter Generator Genquip Gi3300 DSP Inverter Generator Owners Manual...
Page 2: ...page 2 Genquip Gi3300 DSP Inverter Generator...
Page 3: ...pection Oil Replacement 9 Engine Oil Replacement 10 Fuel Filter 11 Fuel Tank Filter 11 Air Filter Maintainence 11 Valve Adjustment 12 Genquip Safety 13 14 15 Operating Procedure 16 Visual Inspection S...
Page 4: ...e 3 Fuel Cap and Vent 4 Fuel On Off Switch 5 AC Ready Pilot Light 6 Oil Warning Light 7 Ground Earth Terminal 8 240 Volt Sockets 9 Engine On Off Switch 10 Choke Knob 11 Recoil Starter ON C HO K E DIGI...
Page 5: ...owly until fuel gauge indicates full Apply fuel cap and turn fuel vent to the ON position WARNING Fuel is high flammable and poisonous DO NOT fill above the top of fuel filler or it may overflow when...
Page 6: ...ickers for a few seconds the engine oil is low Add oil and restart Engine Switch The engine switch controls the ignition system A Ignition circuit is switched on The engine can be started B Ignition c...
Page 7: ...tart a warm engine 3 Hold the choke knob fully out 4 Pull slowly on the recoil starter until it is engaged then pull it briskly 5 After the engine starts warm up the engine until the engine does not s...
Page 8: ...Recoil Starter Check operation 4 Choke Handle Check operation 4 Fuel System Check hose condition look for leaks 4 4 Fittings Fasteners Check and Tighten 4 4 Cooling System Air Check for obstructions...
Page 9: ...eriodically remove and inspect the spark plug 1 Check for discoloration and remove the carbon 2 Check the spark plug type and gap Standard electrode color Tan Color Standard Spark Plug BPR4ES NGK F7RT...
Page 10: ...cap so that the oil can be completely drained 5 Check the drain bolt gasket oil filler gap and O ring 6 Reinstall the oil drain bolt Drain Bolt Torque 12 Ft lbs 7 Add engine oil to the upper level Re...
Page 11: ...l tank cap and filter 2 Clean the filter with solvent if damaged replace 3 Wipe the filter and insert it WARNING Be sure the tank cap is securely tightened Air Filter Maintainence 1 Remove black side...
Page 12: ...asure the depth 3 Insert a feeler gauge into the gap between rocker and valve to measure the valve clearance Valve Clearance Intake 0 1mm 0 004 in Exhaust 0 1mm 0 004in 4 If adjustment is necessary pr...
Page 13: ...ell ventilated area Keep all flammable materials and fuel away from the operating generator Caution of the hot exhaust must be observed as a generator can easily start a fire always locates your gener...
Page 14: ...el cap slowly Do not over fill fuel tank If fuel spillage has occurred during refueling clean the spillage completely and allow sufficient time for any fuel vapors to dissipate Tampering with the fact...
Page 15: ...ionasdfa 1 Never operate the generator whilst wet or expose to damp conditions Clean the generator only when shut down and cooled down completely Do not spray water directly on or near any electrical...
Page 16: ...vel Air filter is not dusted and is free of debris Generator grounded Fuel cap on Start up Disconnect any electrical devices from the generator Generator is on a level surface Exhaust is free from obs...
Page 17: ...sure air or vacuum system CAUTION DO NOT use a forceful spray of water to clean the generator Water can penetrate generator s electrical system which could reduce insulation resistance Possible genera...
Page 18: ...T 3300 Watts FULL TANK OUTPUT 13500 Watts RUN TIME AT 1 2 RATED LOAD 8 5 hours RUN TIME AT RATED LOAD 4 5 hours POWER CONVERSION RATE 85 92 RATED VOLTAGE 240 V RATED FREQUENCY 50 Hz RATED CURRENT 13A...
Page 19: ...ine switch 10 Oil warning light 11 Oil warning unit 12 Oil level gauge 13 Ignition coil 14 Spark plug 15 AC CDI unit 16 Pulsar coil 17 Stepping motor 18 Charge coil 19 DC receptacle 20 Overload indica...
Page 20: ...ion Insufficient Worn out piston and cylinder Consult dealer Generator Won t Produce Power Stop the engine then restart If A C lights continue to flash consult your dealer Storage Long term storage of...
Page 21: ...r engine several times with ignition off to coat the cylinder walls with oil 2 Pull the recoil starter until you feel compression The stop pulling This prevents the cylinder and valves from rusting 3...
Page 22: ...page 23 Genquip Gi3300 DSP Inverter Generator Notes...
Page 23: ...page 24 Genquip Gi3300 DSP Inverter Generator www genquip com au Genquip Warehouse 45 Riverside Road Chipping Norton NSW Call 1300 730 716...