Handheld UV-C Sterilizer 

 

 

 

 
 
INTRODUCTION 

 

UV-C  light  is  electromagnet  radiation  with  wavelengths  shorter than  visible 
light.  UV-C can be separated into various wavelength ranges, with the short-
wavelength  UV-C  considered  to  be  germicidal.    Furthermore,  and  at  the 
specific wavelength range of 260 to 270 nm, UV-C is found to be mutagenic 
to  bacteria,  viruses  and  other  microorganisms.    Germicidal  UV-C  kills  or 
inactivates  microorganisms  by destroying  their  nucleic acids and disrupting 
their DNA, leaving them unable to perform vital cellular functions.  

 

The FirstResponder® Handheld UV-C Sterilizer harnesses the germicidal power of UV-C light, in particular in the 254 
nm wavelength.  This unit uses shortwave UV-C lamps that emit ultraviolet light with the major peak output (~90%) 
band at 253.7 nm. The doped fused quartz glass tubes of the FirstResponder lamps pass the 254 nm radiation (which 
produces  very  low  ozone  levels)  but  blocks  the  185  nm  wavelength  (which  produce  higher  ozone  levels).  The 
FirstResponder®  Handheld  UV-C  Sterilizer  is  intended  for  use  in  disinfection  of  surfaces  in  laboratories,  hospital 
rooms, food-processing areas, or any other places where disinfecting and sterilizing are desired. 

 

 
 
 
 
 
 

 

PRECAUTIONS AND WARNINGS 

(a)

 

Read all instructions before using the devices.  Use of these devices is only for intended purposes as described in this manual. 

(B)

 

DO NOT ATTEMPT TO OPERATE THE FIRSTRESPONDER® UV-C STERILIZER WHEN AND WHERE PEOPLE AND ANIMALS ARE PRESENT AND DIRECTLY 
EXPOSED TO THE UV-C LIGHT.  

(C)

 

FOR SAFE AND PROPER OPERATIONS, DO NOT TAMPER WITH THE UNITS IN ANY WAY.  

(d)

 

The FirstResponder® UV-C Sterilizer

 

emits a small amount of ozone gas when operating, which may give off a little bit of odor.  This is normal, but to avoid eliminate this 

odor if needed, briefly aerate the room after using the sterilizers. 

(e)

 

Do not operate the unit if the cord or plug are damaged, if it is not working properly, or if the unit has been damaged or dropped. 

(f)

 

Do not store the unit outdoors, or use it near open water– for example near filled sinks or water baths. 

(g)

 

Do not attempt to repair or open the unit unless you are a qualified repair technician. 

(h)

 

To avoid injury, handle broken lamps carefully by using protective hand, body, face, and eyewear.  Dispose of broken glass in specialized sharps containers and obey all 
applicable country and city laws. 

 

DOSAGE RECOMMENDATIONS 

 

Different germs and contaminants are susceptible to UV-C radiation at different rates.  To determine the amount of time needed for sterilization, 
consult Table 1 on Page 3. 

SAFETY NOTIFICATION: 

UV-C radiation can damage the superficial tissues of the eye, and care must be taken to avoid excessive exposures to eyes.  Glass or plexiglass eyewear or face 
mask can provide protection in case the motion sensor safety shut off malfunctions.  Also, extended exposure of exposed skin to UV-C make cause damage to 
cellular or tissue DNA and should be avoided by wearing protective clothing while near operating UV-C lamps. 

 

Note and Disclaimer 

*

The FirstResponder® UV-C Sterilizer is not a replacement or substitute for good cleaning practices. Areas to be sterilized must be free of excess contaminants, especially any 

visible liquids or solids (for example bodily fluids, debris or dirt).  The FirstResponder sterilizer can eliminate residual surface contaminants, especially bacterial and fungal, but only if 
the UV-C light is able to directly impact the contaminated surfaces.  

Any surfaces or items that are covered or are behind curtains, glass panels or plastic sheeting will not 

be sterilized by the FirstResponder UV-C units.  

Genlantis makes no claims and offers no guarantees of any kind that the FirstResponder® UV-C Sterilizer will eliminate 100% of 

all contaminants and under all possible circumstances.  For best results, users should closely follow the recommended instructions below.

Specifications 

 

Electrical Specifications 

120 volts AC, 60 Hz. (E500UVCH) / 220 volts AC, 50 Hz (E520UVCH) 

Unit Dimensions (W x D x H) 

Including handle: 18 x 5.5 x 6.5 inches (45.7 x 14 x 16.5 cm) 

UV-C Output / Dosage 

369 µW/cm

@ 12 inches; 735 µW/cm

@ 6 inches 

Weight 

1.5 lbs (0.6 kg) 

Warranty 

1 year 

Catalog #  Description/Content 

Quantity 

E500UVCH 

FirstResponder® Handheld UV-C-C Sterilizer, 110V 

1 Unit 

E520UVCH 

FirstResponder® Handheld UV-C-C Sterilizer, 220V 

1 Unit 

 

Related Products

 

Catalog #

 

FirstResponder® Sterilizer, 110V

 

E4110FRS

 

FirstResponder® Gear Sterilizer

 

E600PCM

 

SteriZAP™ UV-C-C Room Sterilizer, 110V

 

E500UV-CCT

 

SteriZAP™ UV-C-C Desktop Sterilizer, 110V

 

E500UV-CCD

 

FirstResponder® Duffle Bag Sterilizer, medium

 

E600DBM

 

FirstResponder® Duffle Bag Sterilizer, large with wheels

 

E600DBLW

 

 

Reviews: