GenixGreen 5120WH User Manual Download Page 6

- 5 -

4.

INSTALLATION

4.1 UNPACKING AND INSPECTION

Before installation, please inspect the unit. Be sure that everything in the package is not

damaged. The following items inside of package would be received.
01.All-in-one solar system

02.User manual

4.2 PREPARATION.

Please remove the two screws on the back cover of the device before opening it.

4.3 INSTALLATION SITES SELECTION.

Consider the below points before selecting where to install:
1.Do not mount the system on the surface of flammable construction materials.
2.Mount on the surface of solid material.

3.

Install this system at a visible place in order to allow the LCD display to be read at all times.

4.

For proper air circulation and heat dissipate, make sure there is 20cm distance from the

two side, 50cm distance from bottom of the unit.

5.

The ambient temperature should be between 0°C and 55°C to ensure optimal operation.

6.

The recommended installation position is to be adhered to the wall vertically.

7.

Be sure to keep other objects and surfaces as shown in the diagram to guarantee

sufficient heat dissipation and to have enough space for collecting wires.

4.4 AC INPUT/OUTPUT CONNECTION

CAUTION!

Before connecting to AC input power source, please install a separate AC breaker

between system and AC input power source. This will ensure the system can be securely

disconnected during maintenance and fully protected from over current of AC input.

The recommended spec of AC breaker is 3.2KVA 32A. There are two terminal blocks with “IN”

and “OUT” markings. Please do NOT connect input and output connectors wrong.

WARNING!

All wiring must be performed by a qualified personnel. It's very important for

system safety and efficient operation to use appropriate cable for AC input connection. To

reduce risk of injury, please use the proper recommended cable size as below.

Model

Gauge

Cable (mm2)

Torque Value

3.2KVA

10AWG

6

1.2 Nm

4.5 PV CONNECTION PV

CAUTION:

Before connecting to PV modules, please install separately a DC circuit

breaker between system and PV modules.

Summary of Contents for 5120WH

Page 1: ...ES BOX1 5120WH 3 2KVA INVERTER 5KWH LFP BATTERY ALL IN ONE SOLAR ESS USER MANUAL...

Page 2: ...NIT 4 4 AC INPUT OUTPUT CONNECTION 4 5 PV CONNECTION 4 6 FINAL ASSEMBLY 5 OPERATION 5 1 POWER SWITCH 5 2 OPERATION AND DISPLAY PANEL 5 3 LCD DISPLAY ICONS 5 4 LCD SETTING 5 5 FAULT REFERENCE CODE 5 6...

Page 3: ...owing troubleshooting table please send this system back to local dealer or service center for maintenance 5 WARNING Because this system is non isolated only three types of PV modules are adaptable mo...

Page 4: ...xternal WIFI devices 2 2 BASIC SYSTEM ARCHITECTURE The following illustration shows basic application for this system It also includes following devices to have a complete running system Generator or...

Page 5: ...nput Port 7 Movable wheels 8 LCD operate touch display screen 3 WIFI Connectivity Optional This system come equipped with integrated Wi Fi capability which makes it very easy to integrate into a home...

Page 6: ...n position is to be adhered to the wall vertically 7 Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for collecting...

Page 7: ...g proper PV modules please be sure to consider below parameters 1 Open circuit Voltage Voc of PV modules not exceeds maximum PV array open circuit voltage of system 2 Open circuit Voltage Voc of PV mo...

Page 8: ...d well simply press On Off switch located on the button of the case to turn on the unit 5 2 OPERATION AND DISPLAY PANEL The operation and display panel shown in below chart it is on the front panel of...

Page 9: ...utput information 8 Fault indicator 9 About button 10 History button 11 Setting button 12 Diagram button 13 Battery information 5 3 LCD DISPLAY ICONS Icon Description Product model and operation time...

Page 10: ...el status Inverter working status Volume icon CT Power This button includes LCD inverter MPPT version inverter model This button includes generation event help The setting button include language work...

Page 11: ...as the first priority When the solar energy is sufficient the extra energy will charges the battery When solar energy is insufficient for load batteries and solar will supply power at the same time Wh...

Page 12: ...ault Setting range 36v to 50v setting increase or decrease of 0 1V Shutdown Vol 48v mode 42 0vdc default Setting range 36v to 50v setting increase or decrease of 0 1V High Vol Reconnect 48V model 54 0...

Page 13: ...er is not enough the utility will assist it to power loads Note if the utility charging is selected to be 0A the grid connection function will not be available Peak and Valley No charge1 optional No c...

Page 14: ...erload fault 06 Output short circuited or over temperature 07 Battery voltage is too low 08 Inverter soft start failure 09 Bus voltage is too low 10 Battery voltage is too high 11 Over temperature 12...

Page 15: ...is too low 2 Internal fuse tripped 1 Contact repair center for replacing the fuse 2 Re charge battery 3 Replace battery Mains exist but the unit works in battery mode Input voltage is displayed as 0...

Page 16: ...se overload Reduce the number of PV modules in series or the connected load Fault code 02 03 Output abnormal Inverter voltage below than 190Vac or is higher than 260Vac 1 Reduce the connected load 2 R...

Page 17: ...age 450VDC PV operating voltage range 120 450VDC PV normal operating voltage 280 360VDC Normal output voltage 230VAC Output voltage range 230 5 VAC Normal output current 14A Power factor 1 0 Efficienc...

Page 18: ...0Vac 7V High Loss Return Voltage 270Vac 7V Max AC Input Voltage 300Vac Normal Input Frequency 50Hz 60Hz Auto detection Low loss Frequency 40 1Hz Low loss Return Frequency 42 1Hz High loss Frequency 70...

Page 19: ...h 100Ah Rated Voltage 51 2V Discharge characteristic Continuous Current 100A Over current protection 120A Charge characteristic Charge Voltage 56V Charge Current 60A Over charge Protection Single cell...

Page 20: ...1 120 load 10s 121 150 load 3 6s 150 load Transfer time 10ms typical UPS 20ms typical Appliances 10ms UPS 20ms Typical device Protection features Low voltage protection High voltage protection Overloa...

Page 21: ...on conditions 2 The warranty provided not cover any damage or defects caused by owner s abuse misuse or negligent acts 3 The warranty provided not cover owner s modification or dismantling of the prod...

Reviews: