Genio MPS2000 Instruction Manual Download Page 1

Rev 2.00 Nov.2007

Summary of Contents for MPS2000

Page 1: ...Rev 2 00 Nov 2007...

Page 2: ...away from direct sunlight water or moisture or hot or cold air currents 8 If the product is to remain unused for an extended period of time its power supply should be disconnected 9 If repair service...

Page 3: ...nstallation instructions 2 I Connection Diagram of the MPS2000 4 II Control Panel Front Panel 5 Rear Panel 6 III MPS2000 Operations How to play your MPS2000 piano silently 7 8 How to select Pre set 9...

Page 4: ...Connection Diagram of the MPS2000 MPS2000 4 Connection Diagram Mute Lever DC 12V 1 3A Mute Position Mute Lever Real Acoustic Piano Position...

Page 5: ...name or a numeric value for a parameter 5 METRONOME Press to turn the metronome on press again to turn it off 6 RECORD PLAY Control Record and Play functions of the Recorder 7 DATA Modifies the curren...

Page 6: ...DI In Thru Out MIDI connections to external MIDI equipment or computer 3 Keyboard Connects to the signal cable from keyboard 4 DC Jack AC power adapter plugs in here Rear Panel POWER DC 12V 1 3V KEYBO...

Page 7: ...hear your performance through headphones Make sure the AC power adapter is connected to the piano and plugged into an outlet Pull the Mute Lever to play the piano in silent Turn the MPS2000 on by pre...

Page 8: ...her SELECT or SELECT button to select other program sounds Adjust the volume control as desired Enjoy your performance without disturbing other people NOTE 1 When turning on the MPS2000 a few seconds...

Page 9: ...one of the 128 GM sounds MPS2000 9 Press either SELECT or SELECT button to select one of the 16 Pre set sounds Pre set sounds can not be edited by user Press the SELECT and the SELECT button together...

Page 10: ...16 User set sounds that were set in factory when out of factory How to Select User set Press both the DATA and the DATA buttons together then Preset should be U1 Pipe Organ 1 from any sounds U1 Pipe O...

Page 11: ...ns do not work in the Pre set of User set mode How to Select effects or variable sounds Release the PROGRAM button to finish Repeat the same procedure as above to select another sound In order to sele...

Page 12: ...tion of User set Press either DATA or DATA button to adjust the value of the parameter Press the DATA and the DATA buttons together to take off the instrument sound from the selected channel Repeat th...

Page 13: ...ton to fix it and move to the next letter Another way to add input is by pressing the appropriate key as the chart below Press the key that matches the letter Refer to the chart press the RECORD butto...

Page 14: ...Functions of Parameter settings in EDIT mode MPS2000 14...

Page 15: ...MPS2000 15...

Page 16: ...AM button to change the instrument while the Metronome is operating If the display shows the instrument number and name press the applicable buttons to select the new instrument sound you want to play...

Page 17: ...either DATA or DATA button to quickly increase or decrease the tempo With the metronome on and Tempo showing press the SELECT button once Press either DATA or DATA button to adjust the beats measure...

Page 18: ...art below Rhythm Chart I Press the SELECT button again Press either DATA or DATA button to adjust the volume up or down Note 1 If the metronome is on during recording its sound will be heard but it is...

Page 19: ...l erase the recording The previous recording if any will be erased The display shows how long you have been recording in units of seconds Record Press the PLAY button to start playing your last record...

Page 20: ...touch To change from the default Medium setting do this Press and hold the PROGRAM button Press one of the 5 black keys just below middle C to select the new touch Release the PROGRAM button How to c...

Page 21: ...MIDI Implementation Chart MPS2000 21...

Page 22: ...Drum Map MPS2000 22...

Page 23: ...General MIDI Program map MPS2000 23...

Page 24: ...be in the Mute position Make sure that nothing is sitting on the keyboard that might press a key down Preparing for Calibration While holding the PROGRAM button down turn the MPS2000 on After 3 second...

Page 25: ...ECORD button down turn MPS2000 the on After 3 seconds release the RECORD button The display should be as below While wearing headphones to monitor the sound play each key and listen to the volume of t...

Page 26: ...one press the RECORD button again to end key adjustment When the adjustment data is successfully stored the display will change as shown and the piano is ready to play again It will take a few seconds...

Page 27: ...e MPS2000 headphones will now be a mixture of the piano sound and the external source sound Use the volume control on the external source to adjust the external sound volume Use two audio cables to co...

Page 28: ...rder to receive MIDI data from a General MIDI keyboard synthesizer or computer connect a MIDI cable between the MIDI Out port of the external device and the MIDI In port of the MPS2000 See the diagram...

Page 29: ...Trouble shooting MPS2000 29...

Page 30: ...Memo MPS2000 30...

Page 31: ...Memo MPS2000 31...

Page 32: ...121 2 Sannam Ri Gyoha Eup Paju City Gyeonggi Do Korea 413 834...

Reviews: