Maintenance Manual
October 2018
Annual Maintenance Procedures
114
S
®
Booms • Z
®
Booms
Part No. 1268489GT
7 Carefully move the test weights to each
remaining location on the platform. Refer to
Illustration 1.
Result: The platform overload indicator light is
on at the platform and
PLATFORM OVERLOAD
is
displayed at the ground control LCD screen.
The alarm is sounding and the engine should
not start and run.
Note: There may be a 2 second delay before the
overload indicator lights flash and the alarm
sounds.
8 Using emergency power, test all machine
functions from the ground controls.
Result: All ground control functions should not
operate.
Note: Z-135 models before serial number 471
and with software revision 1.00 will not
function using the auxiliary pump.
Note: Z-80 and Z-135 models, all functions
should operate except for primary boom
extend.
9 Using a suitable lifting device, lift the additional
test weight from the platform.
Result: The platform overload indicator light
should turn off at platform controls, there
should be no error message displayed at the
ground control LCD screen and the alarm
should not sound.
Note: There may be an 2 second delay before the
overload indicator lights and alarm turn off.
10 Start the engine and test all machine functions
from the ground controls.
Result: All ground control functions should
operate normally.
11 Using a suitable lifting device, remove all test
weights from the platform.
A-10
Test the Platform Load Sense
System - S-60 HC
Genie specifications require that this procedure be
performed annually OR when the machine fails to
lift the maximum rated load.
Testing the platform overload system regularly is
essential to safe machine operation. Continued use
of an improperly operating platform overload
system could result in the system not sensing an
overloaded platform condition. Machine stability
could be compromised resulting in the machine
tipping over.
Note: Be sure that no load sense system faults
exist prior to performing this procedure.
Note: On a properly functioning machine, the LEDs
on both control modules, located next to the ground
control box, should be off.
1 Remove all weight, tools, accessories and
equipment from the platform.
Note: Failure to remove all weight, tools and
accessories from the platform will result in an
inaccurate test.
2 Turn the key switch to ground control and pull
out the red Emergency Stop button to the on
position at both ground and platform controls.
Summary of Contents for S Series