August 2018
Part No. 57.4400.9220GT
GTH-2506 GTH-3007
6-39
Section 6 Fault Codes
FAULT CODES
SPN
FMI Short Text Detail
523942
9
Timeout Error (BAM to BAM) for CAN-Receive-Frame AT1OGCVol2 information; factors & Sensorcalibration for NOX Sensor
(SCR-system downstream cat; DPF-system downstream cat)
523943
9
Timeout Error (PCK2PCK) for CAN-Receive-Frame AT1OGCVol2 information; factors & Sensorcalibration for NOX Sensor
(SCR-system downstream cat; DPF-system downstream cat)
523946
0
Zerofuel calibration injector 1 (in firing order); maximum value exceeded
523946
1
Zerofuel calibration injector 1 (in firing order); minimum value exceeded
523947
0
Zerofuel calibration injector 2 (in firing order); maximum value exceeded
523947
1
Zerofuel calibration injector 2 (in firing order); minimum value exceeded
523948
0
Zerofuel calibration injector 3 (in firing order); maximum value exceeded
523948
1
Zerofuel calibration injector 3 (in firing order); minimum value exceeded
523949
0
Zerofuel calibration injector 4 (in firing order); maximum value exceeded
523949
1
Zerofuel calibration injector 4 (in firing order); minimum value exceeded
523950
0
Zerofuel calibration injector 5 (in firing order); maximum value exceeded
523950
1
Zerofuel calibration injector 5 (in firing order); minimum value exceeded
523951
0
Zerofuel calibration injector 6 (in firing order); maximum value exceeded
523951
1
Zerofuel calibration injector 6 (in firing order); minimum value exceeded
523960
0
Physical range check high for EGR cooler downstream temperature
523960
0
High exhaust gas temperature EGR cooler downstream; warning threshold exceeded
523960
1
Physical range check low for EGR cooler downstream temperature
523960
1
High exhaust gas temperature EGR cooler downstream; shut off threshold exceeded
523973
14
SCR Tamper detection; derating timer below limit 1
523974
14
SCR Tamper detection; derating timer below limit 2
523975
14
Urea quality; derating timer below limit 1
523976
14
Urea qulaity; derating timer below limit 2
523977
14
Urea tank level; derating timer below limit 1
523978
14
Urea tank level; derating timer below limit 2
523980
14
Bad quality of reduction agent detected
523981
11
Urea-tank without heating function (heating phase)
523982
0
Powerstage diagnosis disabled; high battery voltage
523982
1
Powerstage diagnosis disabled; low battery voltage
523988
3
Charging lamp; short circuit to battery
523988
4
Charging lamp; short circuit to ground
523988
5
Charging lamp; open load
523988
12
Charging lamp; over temperature
523989
0
Fuel Balance Control integrator injector 7 (in firing order); maximum value exceeded