6-38
GTH-2506 GTH-3007
Part No. 57.4400.9220GT
August 2018
Section 6 • Fault Codes
SPN
FMI Short Text Detail
523921
3
Sensor error burner temperature; signal range check high
523921
4
Sensor error burner temperature; signal range check low
523921
11
Sensor burner temperature; plausibility error
523922
3
Burner shut of valve; short circuit to battery
523922
4
Burner shut of valve; short circuit to ground
523922
4
Burner Shut Off Valve; short circuit to ground
523922
5
Burner shut off valve; open load
523922
5
Burner Shut Off Valve; open load
523922
7
Burner Shut Off Valve; blocked closed
523922
7
Burner Shut Off Valve; blocked open
523922
12
Over temperature error on burner shut of valve
523922
12
Burner Shut Off Valve; powerstage over temperature
523929
0
Fuel Balance Control integrator injector 1 (in firing order); maximum value exceeded
523929
1
Fuel Balance Control integrator injector 1 (in firing order); minimum value exceeded
523930
0
Fuel Balance Control integrator injector 2 (in firing order); maximum value exceeded
523930
1
Fuel Balance Control integrator injector 2 (in firing order); minimum value exceeded
523931
0
Fuel Balance Control integrator injector 3 (in firing order); maximum value exceeded
523931
1
Fuel Balance Control integrator injector 3 (in firing order); minimum value exceeded
523932
0
Fuel Balance Control integrator injector 4 (in firing order); maximum value exceeded
523932
1
Fuel Balance Control integrator injector 4 (in firing order); minimum value exceeded
523933
0
Fuel Balance Control integrator injector 5 (in firing order); maximum value exceeded
523933
1
Fuel Balance Control integrator injector 5 (in firing order); minimum value exceeded
523934
0
Fuel Balance Control integrator injector 6 (in firing order); maximum value exceeded
523934
1
Fuel Balance Control integrator injector 6 (in firing order); minimum value exceeded
523935
12
Timeout Error of CAN-Transmit-Frame EEC3VOL1; Engine send messages
523936
12
Timeout Error of CAN-Transmit-Frame EEC3VOL2; Engine send messages
523938
9
Timeout Error (BAM to packet) for CAN-Receive-Frame AT1IGCVol1 information; factors & Sensorcalibration for NOX Sensor
(SCR-system upstream cat; DPF-system downstream cat)
523939
9
Timeout Error (BAM to BAM) for CAN-Receive-Frame AT1IGCVol1 information; factors & Sensorcalibration for NOX Sensor
(SCR-system upstream cat; DPF-system downstream cat)
523940
9
Timeout Error (PCK2PCK) for CAN-Receive-Frame AT1IGCVol1 information; factors & Sensorcalibration for NOX Sensor
(SCR-system upstream cat; DPF-system downstream cat)
523941
9
Timeout Error (BAM to packet) for CAN-Receive-Frame AT1OGCVol2 information; factors & Sensorcalibration for NOX
Sensor (SCR-system downstream cat; DPF-system downstream cat)
FAULT CODES