August 2018
Part No. 57.4400.9220GT
GTH-2506 GTH-3007
6-35
Section 6 Fault Codes
FAULT CODES
SPN
FMI Short Text Detail
523720
2
Sensor urea supply module heater temperature; plausibility error (normal condition)
523720
2
Sensor urea supply module heater temperature; plausibility error (cold start condition)
523720
8
Urea supply module heater temperature; duty cycle in failure range
523720
8
Urea supply module heater temperature; duty cycle in invalid range
523721
2
Sesnor urea supply module temperature; plausibility error (normal condition)
523721
2
Sensor urea supply module temperature; plausibility error (cold start condition)
523721
8
Urea supply module temperature; duty cycle in failure range
523721
8
Urea supply module temperature; duty cycle in invalid range
523721
11
Urea supply module temperature measurement not available
523722
8
Urea supply module PWM signal; period outside valid range
523722
8
Detect faulty PWM signal from Supply Modul
523723
11
Detection of AdBlue filled SCR system in Init-State
523766
9
Timeout Error of CAN-Receive-Frame Active TSC1AE
523767
9
Timeout Error of CAN-Receive-Frame Passive TSC1AE
523768
9
Timeout Error of CAN-Receive-Frame Active TSC1AR
523769
9
Timeout Error of CAN-Receive-Frame Passive TSC1AR
523770
9
Timeout Error of CAN-Receive-Frame Passive TSC1DE
523776
9
Timeout Error of CAN-Receive-Frame TSC1TE -active
523777
9
Passive Timeout Error of CAN-Receive-Frame TSC1TE; Setpoint
523778
9
Active Timeout Errorof CAN-Receive-Frame TSC1TR
523779
9
Passive Timeout Error of CAN-Receive-Frame TSC1TR
523788
0
CAN-Transmit-Frame ComTrbChActr "BusOff-Satus"; Wastegate
523788
0
CAN-Transmit-Frame ComTrbChActr disable error; wastegate
523788
0
CAN-Transmit-Frame ComTrbChActr plausibility error; wastegate
523788
0
Timeout Error of CAN-Transmit-Frame ComTrbChActr; Wastegate
523788
12
Timeout Error of CAN-Transmit-Frame TrbCH; Status Wastegate
523793
9
Timeout Error of CAN-Receive-Frame UAA10; AGS sensor service message
523794
9
Timeout Error of CAN-Receive-Frame UAA11; AGS sensor data
523803
9
Timeout Error of CAN-Receive-Frame RxEngPres; Status burner airpump
523867
12
Timeout Error of CAN-Transmit-Frame UAA1 on CAN 2; Burner Air Pump Control
523895
13
Check of missing injector adjustment value programming (IMA) injector 1 (in firing order)
523896
13
check of missing injector adjustment value programming (IMA) injector 2 (in firing order)
523897
13
check of missing injector adjustment value programming (IMA) injector 3 (in firing order)
523898
13
check of missing injector adjustment value programming (IMA) injector 4 (in firing order)