background image

User Manual

Multi-Card Technology Reader - 13.56MHz, DesFire EV1 / EV2 and EM / HID

6

1.8 Troubleshooting

No response when power up

Discount the power and confirm that the power supply cable is correctly connected (See 
“Wiring” above).
Check the input voltage is sufficient (See “Specifications” above).

Auto Restart

Check the input voltage is sufficient (See “Specifications” above).

Cannot read card number correctly

Check the format setting on the controller if it is the same as the card format. Use ap-
proved card (known format and Facility Code) to test.
Check if the shield cable is correctly connected to Classis Ground at ONE point only.

Reader beeps but No card data info

Check if data 0 & data 1 cable is correctly connected (See “Wiring” above).
Check the input voltage at the card reader end is correct (See “Specifications” above).

Buzzer error

Check if the buzzer cable is correctly connected (See “Wiring” above).

Back lit error

Check the Led cable is correctly connected (See “Wiring” above).
Use Default Configuration Card to set it back to normal.

Keypad no response

Power off reader for 5 seconds and power on again