  6.  FAQ

 

Error item 

Check list 

When power is not 

turned on 

Press and hold the power button for more than 3 seconds. A short push will not power up. 

Please make sure that 9V battery is installed. 

Make sure that the battery power is at least 7 V.  
If it is below 7 V, the power is not turned on or the [batt] message is output. 

When the screen is 

dimmed 

Please replace the battery. Depending on the voltage consumption of the battery, the screen 
may become blurred. 

When the [batt] 

phrase is displayed 

This indicates when the battery should be replaced. Please replace the battery. 

When the measured 

value is [0.0] 

Check that the light source is on. 
For UV index meters, measurements may be impossible on cloudy days. 

Make sure that the incident surface of the sensor probe is perpendicular to the light source. 

Check the detection wavelength range of the measuring instrument and the wavelength of the 
light source.  
The detection wavelength range can be found on page 4 of the manual and on the back of the 
measuring instrument. 

When the measured 

value differs 

depending on the 

light source 

Please check page 5 relative response curve. 
Even if included in the measurement range, the output value may vary depending on the 
wavelength of the light source. 
The calibration light source information for the measuring instrument can be found on  page 4. 

When the measured 

value is measured 

low 

In the case of a UV index meter, the measured value may be low or not measured on cloudy 
days.  

Make sure that the sensor measuring surface is positioned perpendicular to the light source.  
If the angle is tilted, accurate measurements will not be made. 

Check if there is foreign substance on the sensor measurement surface. 
Foreign matter such as oil or dust can cause a decrease in light quantity. 

When power is off 

during use 

If there is no input value for more than 90 seconds, the power is automatically turned off.  
In this case, it is in normal operation. 

 If any problem occurs other than the above, please contact the sales company or A / S center. 

  7. A/S Request in Case of Product Failure

 

    -  Should any failure is found in product,  please call the sales company  or customer center for A/S.  
    -  Product warranty period is 1 year from the date of procurement with no charge.   
        However, failure which  is caused by user’s misuse or carelessness within warrant period or any failure   
        after the warrant period  shall be chargeable for it’s A/S. 
    -  Product inquiry and on-line customer service Tel : +82-42-862-3982, Fax : +82-42-862-2982 
        E-mail : 

[email protected]

    Website  : 

http://www.geni-uv.com

 

 

Page 11 

Summary of Contents for GENUV MG-07.1

Page 1: ...Genicom Co Ltd 2018 rev 1 SA HAN Manual Radiometer 7 1 GUVX T1XGS7 1 L GUVX T1XGS7 1 LA9...

Page 2: ...Genicom Co Ltd 2018 rev 1 SA HAN 1 MG 07 1 GUVX T1XGS7 1 L Manual _ English Page 2 11 3 MG 07 1 GUVX T1XGS7 1 LA9 Manual _ English Page 12 21 Contents Page 1...

Page 3: ...Genicom Co Ltd 2018 rev 1 SA HAN MG 07 1 GUVX T1XGS7 1 L Manual Page 2...

Page 4: ...4 2 Back side 5 Product Operation Method 5 1 Battery check 5 2 Precautions for battery replacement 5 3 Power ON or OFF 5 4 Function button 5 5 Reset cumulative light intensity Dose or maximum light in...

Page 5: ...ection Power range 0 00 99 99 0 50 0 UVI Spectral detection range 230 395 nm 220 320 nm 220 280 nm 220 320 nm 330 445 nm 220 320 nm Calibration peak point 365 nm LED 306 nm Lamp 254 nm Lamp 285 nm LED...

Page 6: ...ct the meter to extremes in temperature humidity shock or dust When the surface contamination of the product wipe with a soft clean cloth Keep sensor free of oil dirt etc Do not disassemble or modific...

Page 7: ...D This is a four digit LCD display Function Display LED Red Absolute Power mW cm2 Green Dose J cm2 Yellow Max Power mW cm2 Power Button Turns the power on off Function Button Switches the display of A...

Page 8: ...Product name Wavelength measuring range Product Information Sticker Battery Cover Model No GUVX T1XS7 1 L Type UV Index Meter Detection Range XXX XXX nm Power Range 0 100 0 NIST Traceable Made in KORE...

Page 9: ...8 5 1 Battery check Remove the battery cover on the back of the main unit and check if the 9V battery is included 5 2 Precautions for battery replacement Pulling the connector forcibly can cause it t...

Page 10: ...order ex Absolute power Dose Max power Absolute power Push the power button for 3 seconds Power ON Absolute power Dose Max power 5 5 Reset cumulative light intensity Dose or maximum light intensity M...

Page 11: ...he sensor is positioned perpendicular to the UV light source or solar light that you want to measure 5 7 Notify when to replace the battery If the batt message is displayed on the LCD or if the screen...

Page 12: ...ange the output value may vary depending on the wavelength of the light source The calibration light source information for the measuring instrument can be found on page 4 When the measured value is m...

Page 13: ...Genicom Co Ltd 2018 rev 1 SA HAN Page 12 MG 07 1 GUVX T1XGS7 1 LA9 Manual...

Page 14: ...k side 5 Product Operation Method 5 1 Battery check 5 2 Precautions for battery replacement 5 3 Sensor probe connection 5 4 Power ON or OFF 5 5 Function button 5 6 Reset cumulative light intensity Dos...

Page 15: ...99 99 0 50 0 UVI Spectral detection range 230 395 nm 220 320 nm 220 280 nm 220 320 nm 330 445 nm 220 320 nm Calibration peak point 365 nm LED 306 nm Lamp 254 nm Lamp 285 nm LED 385 405 nm LED Solarsi...

Page 16: ...ect the meter to extremes in temperature humidity shock or dust When the surface contamination of the product wipe with a soft clean cloth Keep sensor free of oil dirt etc Do not disassemble or modifi...

Page 17: ...Function Display LED Red Absolute Power mW cm2 Green Dose J cm2 Yellow Max Power mW cm2 Power Button Turns the power on off Function Button Switches the display of Absolute power mW cm2 Dose J cm2 an...

Page 18: ...oduct name Wavelength measuring range Product Information Sticker Battery Cover Model No GUVX T1XS7 1 LA9 Type UV Index Meter Detection Range XXX XXX nm Power Range 0 100 0 NIST Traceable Made in KORE...

Page 19: ...od 5 1 Battery check Remove the battery cover on the back of the main unit and check if the 9V battery is included 5 2 Precautions for battery replacement Pulling the connector forcibly can cause it t...

Page 20: ...ck sound Page 19 5 4 Power ON or OFF If you push the power button for 3 seconds translate the device ON OFF 5 5 Function button If push the function button the function display will change in order ex...

Page 21: ...ight intensity Max Power Select the function that you want And push the function button for 3 seconds Or turn the power off and on 90 The sensor is located on top of the sensor probe The measurement s...

Page 22: ...placed Please replace the battery When the measured value is 0 0 Check that the light source is on For UV index meters measurements may be impossible on cloudy days Make sure that the incident surface...

Page 23: ...Genicom Co Ltd 2018 rev 1 SA HAN MEMO...

Page 24: ...Genicom Co Ltd 2018 rev 1 SA HAN...

Reviews: