background image

Elite Steam 

+03U221903

 REV 2.

1

 

Instant steam production; 

voltage-phase-frequency, kW 

2.5 kg/h (5.5 lbs/hr): 110 VAC 1-phase 50-60 Hz, 1.86 kW

5.4 kg/h (12 lbs/hr): 230 VAC 1-phase 50-60 Hz, 4.05 kW

Notes

Outlet pressure limits (Pa)

950 Pa / 3

.81

 in WC

For duct only

Dimensions (mm )

600 x 341 x 204mm (24” x 14” x 8”)

(Height x Width x Depth)

Weight empty/packaged/

installed with water

8/10/12 kg

18/22/26 lbs.

IP class

IP20

Electrode power cables

12 

  AWG

Power relays

 2x 30 Amp

On board

Ground connection

Screw

Input water type

Potable water

No demin. or softened water

Conductivity range

125 to1250 µS/cm

Special cylinders for cond. < 350

Water fill connection

¾” G

Adapter to ¾” FPS

Water fill - instant fl

ow

Drain connection

32  mm 1.25”

Adjustable from horizontal to vertical.

May be from back or bottom of unit.

Drain water temp

< 60°C

Drain tempering device

Drain flow

Max 1.3 gpm

Embedded fan fl

ow

120 m³/hr

71 cfm

Direct Room Discharge Only

Serial communication

RS-485

Tab. 7.d

8. TECHNICAL SPECIFICATIONS

9.  LIMITED WARRANTY

DS and RS  Humidifiers,  if properly registered by the return of the attached warranty registration to General Filters, Inc., are warranted to the 

consumer against defects in materials and workmanship for a period of two years from the date of installation, so long as the product has 

been installed and operated in accordance with all appropriate manuals and wiring diagrams.  Replacement of routinely replaceable parts 

such as steam cylinders and gaskets, are not covered by this limited warranty or any other warranties.  Any other defective parts will be 

repaired without charge except for removal, reinstallation and transportation costs.  To obtain repair service under this limited warranty, the 

consumer must send the defective part to General Filters, Inc.

THERE ARE NOT EXPRESS WARRANTIES COVERING THIS HUMIDIFIER OTHER THAN AS SET FORTH ABOVE.  THE IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.  

THE MANUFACTURER ASSUMES NO LIABILITY IN CONNECTION WITH THE INSTALLATION OR USE OF THIS PRODUCT, EXCEPT 

AS STATED IN THE LIMITED WARRANTY.  THE MANUFACTURER WILL IN NO EVENT BE LIABLE FOR INCIDENTAL OR 

CONSEQUENTIAL DAMAGES.

This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state.  Some states do not 

allow either limitations on implied warranties, or exclusions from incidental or consequential damages, so the above exclusion and limitation 

may not apply to you.

Any questions pertaining to this limited warranty should be addressed to General Filters, Inc.  General Filters, Inc. has elected not to make 

available the informal dispute settlement mechanism which is specified in the Magnuson-Moss Warranty Act.

0.35 - 0.45 l/min 0.09- 0.12 gpm

 Max 4 l/min

24

<140°F

Summary of Contents for Elite Steam DS15

Page 1: ...Residential Steam Humidi ers User manual Elite Steam...

Page 2: ...03U221903 REV 2 1 REMOVE BEFORE INSTALLING REMOVE BEFORE INSTALLING REMOVE BEFORE INSTALLING REMOVE BEFORE INSTALLING LATCH THE CYLINDER CLAMP REMOVE BEFORE INSTALLING Warning If present remove the fo...

Page 3: ...BEFORE beginning installation Check for shipping damage to cartons Mark the shipping waybill accordingly Open cartons and check for any hidden damage Mark the shipping waybill accordingly Check packi...

Page 4: ...4 Elite Steam 03U221903 REV 2 1...

Page 5: ...sic Operation 11 9 14 17 17 17 17 5 OPERATING ELITE STEAM 5 1 Displaying Information 5 2 Changing The Maximum Production 18 5 3 Activating Manual Drain 18 5 4 Resetting the Hour Counter 18 5 5 Using t...

Page 6: ...oo much as the water fills the cylinder the drain valve 13 will be activated to drain away some water and reduce the current flow to acceptable levels Note that any time the drain valve is activated t...

Page 7: ...ife will be accompanied by the need to replace filter elements with each cylinder change Humidity load demands have an effect on cylinder life Normal installations where humidity capacity is properly...

Page 8: ...lons per day 12 Lbs per hour 220 240v Humidifier only Kit selection required Duct steam injection 15 gallons per day 5 5 Lbs per hour 115 120v Duct steam injection 35 gallons per day 12 Lbs per hour 2...

Page 9: ...mm 6 E 24 m m 0 0 6 F max 0 2 Degrees Tab 3 a Millimeters Inch A B C Kilograms Pounds Weight empty Weight packaged Weight installed with water Tab 3 c Duct Steam Injection Room Steam Discharge Unit D...

Page 10: ...102 4 600 23 5 8 35 1 3 8 69 2 3 4 48 4 0 1 5 8 5 0 2 23 7 8 3 0 1 1 8 1 7 8 61 2 3 8 16 5 8 70 2 3 4 65 21 2 60 2 3 8 23 7 8 94 3 5 8 81 31 4 50 2 9 3 8 54 21 8 24 7 8 40 1 5 8 Fig 3 f 3 2 2 Fasteni...

Page 11: ...and conductivity of water Water Conductivity must be matched by specifications of the steam cylinder Check or know the water conductivity of the proposed site before installation Replace the steam cy...

Page 12: ...ple fact when running the steam hose steam naturally flows uphill and condensate naturally flows downhill Run the steam hose or piping to avoid any kinks sharp elbows or low spots that could collect t...

Page 13: ...ings show the minimum recommended distances to avoid the flow of humidified air from coming into direct contact with persons lights electrical appliances and surfaces before the steam has been totally...

Page 14: ...nection of any simple or automatic humidistat and safety devices such as high limit humidistat air flow proving switch and remote on off The humidi er is operated by the closing of a mechanical humidi...

Page 15: ...tches are used then a jumper must be installed between AB AB DO NOT apply any voltage to AB AB 3 6 3 Connect the ADCD humidistat for Modulating Operation To select signal modulating see Fig 3 y Connec...

Page 16: ...s L1 L 2 GROUND Power supply and Ground connections Power supply 110 VAC 1 phase 50 60Hz 1 86kW or 230VAC 1 phase 50 60Hz 4 05kW KEY Programming port Connecting to Programming port or supervisor GND N...

Page 17: ...eter values 11 ON OFF button 12 Reset button to reset alarms and access parameters 13 Level of output 33 66 100 14 Fan relay is activated 4 3 Starting Elite Steam Insure that the external power is tur...

Page 18: ...aximum Production and exit to the normal operating mode 5 3 Activating Manual Drain Press and hold the drain button on the front of the unit until the cylinder is drained Note Water will continue to f...

Page 19: ...et the alarms although still active alarms will continue to display 5 Using the E2 Humidistat 5 Press toselect OFF MANUALor AUTO mode if outdoor sensor is connected OFF mode The humidifier is turned o...

Page 20: ...r drain is blocked 2 The supply water or over ow circuit has leaks 3 The condensate drain pipe does not bring the water back to the drain pan 4 The steam hose is not properly fastened to the cylinder...

Page 21: ...l before touching it or use protective gloves To replace the cylinder 1 Completely drain the cylinder by pressing and holding the drain button until the cylinder is empty 2 Turn the humidi er off and...

Page 22: ...19 BLOWER FILTER KIT 6 7536 35 20 INTERNAL STEAM DISTRIBUTOR MANIFOLD FOR ROOM VERSION 7 7537 15 3 FILL TEMPERING VALVE ASSEMBLY 110 1 7 7538 35 3 FILL TEMPERING VALVE ASSEMBLY 230 1 8 7539 15 4 DRAI...

Page 23: ...T GRILL FOR RMB 7525 DMNKIT DUCT MOUNT KIT FOR GENERALAIRE DS35 AND DS15 7545 RMB15 REMOTE MOUNT BLOWER KIT 110 1 FOR GENERAL AIRE DS15 7540 RMB35 REMOTE MOUNT BLOWER KIT 230 1 FOR GENERAL AIRE DS35 7...

Page 24: ...ed and operated in accordance with all appropriate manuals and wiring diagrams Replacement of routinely replaceable parts such as steam cylinders and gaskets are not covered by this limited warranty o...

Page 25: ...Elite Steam 03U221903 REV 2 1 25...

Page 26: ...Elite Steam 03U221903 REV 2 1 NOTES 26...

Page 27: ...Elite Steam 03U221903 REV 2 1 27...

Page 28: ...C 43800 GRAND RIVER AVE NOVI MICHIGAN 48375 1115 WWW GENERALAIRE COM CANADIAN GENERAL FILTERS LTD 39 CROCKFORD BLVD SCARBOROUGH ONTARIO M1R3B7 WWW CGFPRODUCTS COM Agency Form 35 5 Rev 2 0 Elite Steam...

Reviews: