TS4000H
13
Table 5: Gas Combination Table
WARNING:
When operating the TS4000H under the above conditions, all personnel
operating and maintaining the units should be notified of the cross-sensitivity
issues that are present at the site.
CAUTION:
Do not paint the TS4000H assemblies. If the Base Unit is painted, the LED
display cannot be read. If the Interface Module is painted, the gas is not able to
diffuse into the sensor. Chlorine, Chlorine Dioxide, and Hydrogen Chloride cell
types may be sensitive to humidity variation (See Table 44 for Environmental
Specifications).
3.3 Installation Overview
The TS4000H is shipped without the electrochemical cell installed. The electrochemical cell
must be installed into the Interface Module and calibrated for proper operation. For wiring
connections, refer to Section 3.5. For calibration instructions, refer to Section 4.9.
Cell Type
Gas Combinations
Ammonia
Carbon Monoxide
Hydrogen Sulfide
Sulfur Dioxide
Applied Indicates Applied Indicates Applied Indicates
50 ppm
0 ppm
25 ppm
7 ppm
10 ppm
0 ppm
Carbon
Monoxide
Ethylene Hydrogen
Nitric
Oxide
Applied Indicates Applied Indicates Applied Indicates
100 ppm
75 ppm
100 ppm
60 ppm
100 ppm
20 ppm
Chlorine
Nitrogen Dioxide
Applied Indicates
100 ppm
120 ppm
Chlorine
Dioxide
Nitrogen Dioxide
Applied Indicates
100 ppm
120 ppm
Hydrogen
Carbon Monoxide
Ethylene
Nitric Oxide
Applied Indicates Applied Indicates Applied Indicates
100 ppm
200 ppm
100 ppm
75 ppm
10 ppm
≤
2 ppm
Hydrogen
Chloride
Sulfur Dioxide
Applied Indicates
100 ppm
35 ppm
Hydrogen
Sulfide
Sulfur Dioxide
Ammonia
Carbon Monoxide
Applied Indicates Applied Indicates
Applied
Indicates
100 ppm
100 ppm
100 ppm
0 ppm
100 ppm
0 ppm
Nitric
Oxide
Hydrogen Sulfide
Nitrogen Dioxide
Applied Indicates Applied Indicates
100 ppm
35 ppm
100 ppm
25 ppm
Nitrogen
Dioxide
Chlorine
Applied Indicates
100 ppm
90 ppm
NOTE: All values are approximations based on experimental data.