GM9907-L5
bulk scale controller user’s manual
- 60 -
6. Bulk ACUM process
GM9907-L5
bulk scale controller in running state can auto control coarse, fine feed
material
,
discharge material all metering ACUM process.Two working mode
:
Receipt mode
and Delivery mode. In stop state
,
user click statistics enter statistics in&out interface.
running
“
in&out mode
”
option. Support “Stock-in”, “Stock-out”mode.
Mode
Stock-in
Stock-out
Differ
No need set Receipt ACUM value
Need to set Delivery ACUM value
(
range0~999999999
)
Continuous Receipt will be
provided until the external input of
"E-stop or STOP" signal, the
machine will not stop
After the DeliveryACUM quantity is
completed, the controller will output Alarm
then Pause, and the controller will display
"Stock-Out Done" and stop after Clear Alarm.
E-Stop
During the operation, enter e-stop
Controller will stop immediately,
start again will continue the last
in&outACUM weight ACUM.
During operation, enter [e-stop], controller will
enter stop state, start again will continue the
last in&outACUM weight ACUM; If want to
change the DeliveryACUM quantity, you can
modify the new Delivery quantity ACUM
quantity through the Controller panel after
stopping the machine. After modification, press
[Start] to make the controller continue to run
and complete the Delivery process. When
modifying the ACUM quantity, the controller
saves the ACUM weight of the delivered
quantity (this value cannot be Zero, otherwise,
the controller defaults to re-deliver from 0 after
Zero).
Stop
During operation, enter Stop Controller to stop charging immediately, enter value and
discharge State, output Alarm then Pause after discharge is completed, and the
controller displays "Delivery Done" to complete in&out. User can press e-stop or
make Clear Alarm valid to Clear the Alarm and return the stop state. Start again need
to clear the last "in&outACUM" before starting the next round of feeding