Owner’s Manual for Portable Generator
13
Generator Shut Down
1. Turn main breaker switch Off.
2. Switch engine start switch to Off.
3. Turn fuel valve Off.
Emergency Shutdown Procedure
1. Press down on small red lever on lower
engine controls (near recoil handle and
dipstick) to the Stop position.
2. Turn main breaker switch Off.
3. Switch engine start switch to Off.
4. Turn fuel valve Off.
To re-start engine, the engine control lever
must be moved to Run (B). See
.
Low Oil Pressure Switch
The engine is equipped with a low oil pressure
switch that shuts down the engine automati-
cally when the oil level drops below a speci-
fied level. The engine will not run until the oil
has been filled to the proper level.
If the engine shuts down and there is sufficient
fuel, check engine oil level.
(000136)
CAUTION
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.