Generac Power Systems Whisper - Test UL 2200 Specification Sheet Download Page 1

 GENERAC 6.8L ENGINE

•  All input connections in one single area
•  High coolant temperature shutdown
•  Low oil pressure shutdown
•  Low coolant level automatic shutdown
•  Low fuel pressure
•  Overspeed automatic shutdown
•  Adjustable cranking timer
•  Adjustable exercise timer
•  Oil drain extension
•  Cool flow radiator
•  Closed coolant recovery system

• UV/Ozone 

resistant 

hoses

•  Watertight state of the art electrical connectors
•  Mainline circuit breaker
•  Oil drain extension to frame rail
•  Radiator drain extension
•  Battery charge alternator
•  2 Amp static battery charger
•  Battery, battery rack and battery cables
•  Fan and belt guards
• Isochronous 

governor

•  Flex fuel line pigtail

STANDARD EQUIPMENT

Naturally Aspirated

Gaseous Fueled

•  Innovative design and fully prototype tested
•  UL 2200 Listed
•  Solid state frequency compensated voltage regulator
•  Dynamic and static battery charger
•  Sound attenuated acoustically designed enclosure
•  Whisper-Test™ for low noise level exercise
•  Acoustically designed engine cooling system
•  High flow low noise factory engineered exhaust system
• State of the art digital control system with H-100 microprocessor
 control 

panel

•  Watertight electrical connectors
•  Rodent proof construction
• High efficiency, low distortion Generac designed alternator
•  Vibration isolated from mounting base
•  Matching Generac transfer switches engineered and tested
 

to work as a system

•  All components easily accessible for maintenance
•  Electrostatically applied powder paint
•  Built-in kW, kVAR and power factor meters

FEATURES

70 kW 

60 Hz

Liquid Cooled Gas Engine Generator Sets

Standby Power Rating

Whisper-Test

Low Speed Exercise

61 dB(A) at 23 feet

 

 UL 2200 Listed

COMMERCIAL SERIES

Transfer Switch is sold separately

Summary of Contents for Whisper - Test UL 2200

Page 1: ...ested UL 2200 Listed Solid state frequency compensated voltage regulator Dynamic and static battery charger Sound attenuated acoustically designed enclosure Whisper Test for low noise level exercise Acoustically designed engine cooling system High flow low noise factory engineered exhaust system State of the art digital control system with H 100 microprocessor control panel Watertight electrical c...

Page 2: ...il pressure shutdown High coolant temperature shutdown Overvoltage Overspeed Low coolant level Low coolant level Not in auto position flashing light Exercise speed ATS selection INTERNAL FUNCTIONS I2T function for alternator protection from line to neutral and line to line short circuits Emergency stop Programmable auto crank function 2 wire start for any transfer switch Communicates with the Gene...

Page 3: ...IR REQUIREMENTS Flow at rated power 60 Hz cfm 205 SOUND EMISSIONS IN DBA db A 23 feet in exercise mode 61 db A 23 feet at normal operating load 65 EXHAUST Exhaust flow at rated output 60 Hz cfm 557 Exhaust temp at muffler outlet F 890 ENGINE PARAMETERS Rated synchronous RPM 60 Hz 1800 HP at rated KW 60 Hz 110 7 POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration 3 for every 10 C above C 2...

Page 4: ...480 3 ø 125 300 mc to 6 INSTALLATION LAYOUT Note Door access from both sides COMMERCIAL 70 kW UNIT WEIGHT Steel 2185 lbs Aluminum 2040 lbs 2007 Generac Power Systems Inc All rights reserved All specifications are subject to change without notice Bulletin 0174670SBY Printed in USA 06 07 08 07 GENERAC POWER SYSTEMS INC P O BOX 297 WHITEWATER WI 53190 www guardiangenerators com COMMERCIAL SERIES ...

Reviews: