Generac Power Systems SD350 User Manual Download Page 1

1 of 5

Industrial Diesel Generator Set

EPA Certified Stationary Emergency

350 kW Diesel

Standby Power Rating

438kVA    350kW    60Hz

Prime Power Rating*

394kVA    315KW    60Hz

features

benefits

primary codes and standards

Generator Set

=

  PROTOTYPE & TORSIONALLY TESTED 

4

 

PROVIDES A PROVEN UNIT

=

  UL2200 TESTED 

4

 

ENSURES A QUALITY PRODUCT

=

  RHINOCOAT PAINT SYSTEM 

4

 

IMPROVES RESISTANCE TO ELEMENTS

=

  WIDE RANGE OF ENCLOSURES AND TANKS 

4

 

PROVIDES A SINGLE SOURCE SOLUTION

Engine

=

  EPA COMPLIANT 

4

 

ENVIRONMENTALLY FRIENDLY

=

  INDUSTRIAL TESTED, GENERAC APPROVED 

4

 

ENSURES INDUSTRIAL STANDARDS

=

  POWER-MATCHED OUTPUT 

4

 

ENGINEERED FOR PERFORMANCE

=

  INDUSTRIAL GRADE 

4

 

IMPROVES LONGEVITY AND RELIABILITY

Alternator

=

  TWO-THIRDS PITCH 

4

 

ELIMINATES HARMFUL 3RD HARMONIC

=

  LAYER WOUND ROTOR & STATOR 

4

 

IMPROVES COOLING

=

  CLASS H MATERIALS 

4

 

HEAT TOLERANT DESIGN

=

  DIGITAL 3-PHASE VOLTAGE CONTROL 

4

 

FAST AND ACCURATE RESPONSE

Controls

=

  ENCAPSULATED BOARD W/ SEALED HARNESS 

4

 

EASY, AFFORDABLE REPLACEMENT

=

  4-20mA VOLTAGE-TO-CURRENT SENSORS 

4

 

NOISE RESISTANT 24/7 MONITORING

=

  SURFACE-MOUNT TECHNOLOGY 

4

 

PROVIDES VIBRATION RESISTANCE

=

  ADVANCED DIAGNOSTICS & COMMUNICATIONS 

4

 

HARDENED RELIABILITY

*EPA Certified Prime ratings are not available in the U.S. or its Territories for engine model year 2011 and beyond

SD350

Generator image used for illustration purposes only

Summary of Contents for SD350

Page 1: ... STANDARDS POWER MATCHED OUTPUT 4 ENGINEERED FOR PERFORMANCE INDUSTRIAL GRADE 4 IMPROVES LONGEVITY AND RELIABILITY Alternator TWO THIRDS PITCH 4 ELIMINATES HARMFUL 3RD HARMONIC LAYER WOUND ROTOR STATOR 4 IMPROVES COOLING CLASS H MATERIALS 4 HEAT TOLERANT DESIGN DIGITAL 3 PHASE VOLTAGE CONTROL 4 FAST AND ACCURATE RESPONSE Controls ENCAPSULATED BOARD W SEALED HARNESS 4 EASY AFFORDABLE REPLACEMENT 4 ...

Page 2: ...tem Oil Filter Type Full Flow System Voltage 24VDC Crankcase Capacity L qts 35 36 9 Battery Charging Alternator Std Battery Size at 0ºC 1155 CCA Battery Group 8D Battery Voltage 2 12VDC Ground Polarity Negative ALTERNATOR SPECIFICATIONS Standard Model 520 mm Generac Voltage Regulator Type Digital Poles 4 Number of Sensed Phases 3 Field Type Revolving Regulation Accuracy Steady State 0 25 Insulatio...

Page 3: ...Load gph lph 36 900 25 8 4 31 8 25 7 56 28 8 50 14 5 54 9 50 13 05 49 6 Total Fuel Pump Flow Combustion Return 75 20 1 76 1 75 18 09 68 5 31 gph 100 25 3 95 8 100 22 77 86 3 Refer to Emissions Data Sheet for maximum fuel flow for EPA and SCAQMD permitting purposes STANDBY PRIME Coolant Flow per Minute gpm lpm 145 552 145 552 Heat Rejection to Coolant BTU hr 932 760 840 590 Inlet Air cfm m3 min 19 ...

Page 4: ...el Touchscreen na Digital G 200 Paralleling Control Panel Touchscreen na Programmable Crank Limiter Std 21 Light Remote Annunciator Opt Remote Relay Panel 8 or 16 Opt 7 Day Programmable Exerciser Std Special Applications Programmable PLC Std RS 232 Std RS 485 Std All Phase Sensing DVR Std Full System Status Std Utility Monitoring Req H Transfer Switch Std 2 Wire Start Compatible Std Power Output k...

Page 5: ... 58 132 9248 27 693 181 58 144 9551 37 946 208 58 147 11195 52 1325 278 58 147 12028 Tank Options MDEQ OPT Florida DERM DEP OPT Chicago Fire Code OPT IFC Certification CALL ULC CALL Other Custom Options Available from your Generac Industrial Power Dealer All measurements are approximate and for estimation purposes only Weights are without fuel in tank Sound levels measured at 23ft 7m and does not ...

Reviews: