DON’T OVERLOAD THE

GENERATOR

NOTE: Refer to this section when you are using the
generator without the Power Transfer System. Refer to
the Power Transfer System owner’s manual when operating
the generator in conjunction with the Power Transfer
System. Ask your Power Transfer System installer to review
load management techniques.

Overloading a generator in excess of its rated wattage
capacity can result in damage to the generator and/or
connected electrical devices. Observe the following, to
prevent overloading the unit:

• Add up the total wattage of all electrical devices to be

connected at one time.This total should NOT be greater
than the generator’s wattage capacity.

• If the appliance, tool or motor does not give wattage,

multiply 120 Volts times ampere rating to determine
watts (volts x amps = watts).

• The rated wattage of lights can be taken from wattage

listed on the light bulbs.The rated wattage of tools,
appliances and motors can usually be found on a data
plate or decal affixed to the device. Use Figure 13 below
as a general reference.

• Some electric motors, such as induction types, require

about three times more watts of power for starting than
for running.This surge of power lasts for only a few
seconds when starting such motors. Be sure you allow
for this high starting wattage when selecting electrical
devices to connect to your generator. First figure the
watts needed to start the largest motor. Add to that
figure the running watts of all other connected loads.

Recreational/Home Uses
Tool/Appliance....................................................Watts
AM/FM clock radio ....................................................................50
Light bulb....................................................................................100
Fan................................................................................................200
20" color TV ..............................................................................400
*Deep freezer ...........................................................................500
Personal computer and 15" monitor...................................800
*1/3 hp furnace fan blower ....................................................800
Microwave oven........................................................................800
*18 cu ft refrigerator...............................................................800
Sump pump..............................................................................1000
Electric skillet..........................................................................1250
*½ hp water well pump .......................................................1400
*12,000 Btu window air conditioner ................................1400
Space heater............................................................................1800
Electric water heater ............................................................4000

Professional/Contractor Uses
Tool/Appliance....................................................Watts
*1/3 hp airless sprayer ............................................................600
3/8" hammer drill .....................................................................600
Variable speed Sawzall® .........................................................960
½" power drill ........................................................................1000
Quartz-halogen work light ..................................................1000
Belt sander...............................................................................1200
7 ¼" circular saw ...................................................................1500
7 ¼" worm drive saw ...........................................................1600
*1½ hp air compressor ........................................................1800
*10" power miter saw...........................................................1800
6" bench grinder.....................................................................1800
*6" table planer.......................................................................1800
*10" table/radial arm saw .....................................................2000
Wire feed welder...................................................................2400
* allow 3 times listed watts for starting this device

Figure 13 — Wattage Reference Guide

Summary of Contents for 1277-0

Page 1: ...safety messages that follow this symbol to avoid possible injury or death Model No 1277 0 7 200 Watt Mobile Backup Power System Manual No B4678 Revision 2 06 20 2001 Visit our Generac website www gene...

Page 2: ...erator is warranted for standards set by the Environmental Protection Agency For warranty information refer to the engine owner s manual SAFETY RULES This generator set was designed and manufactured f...

Page 3: ...of clearance on all sides of generator even while operating unit outdoors or you could damage the unit Never start or stop the unit with electrical loads connected to receptacles with the connected d...

Page 4: ...rton fillers etc Remove the generator from the shipping carton CARTON CONTENTS Check all contents If any parts are missing or damaged call the generator helpline at 1 800 270 1408 The Generator Power...

Page 5: ...and the tires are at the proper inflation The operating range should be 15 40 PSI INSTALLING TRAY AND BATTERY NOTE The generator can be started manually If you choose not to use the electric start fea...

Page 6: ...hot Do Not light a cigarette or smoke when filling the fuel tank WARNING Do Not overfill the fuel tank Always allow room for fuel expansion Use regular UNLEADED gasoline with the generator engine Do...

Page 7: ...foam precleaner to limit the amount of dirt and dust that gets in the engine Choke Lever Used when starting a cold engine Circuit Breakers AC Each receptacle is provided with a circuit breaker to prot...

Page 8: ...ull slowly until slight resistance is felt Then pull rapidly one time only to start engine If engine starts proceed to step 7 If engine fails to start proceed to step 6 6 Move the choke lever to Half...

Page 9: ...dew point your generator may experience icing of the carburetor and or the crankcase breather system In an emergency use the original shipping box as a temporary shelter Cut off all flaps Cut out one...

Page 10: ...olts 7200 watts of power 7 2 kW at 30 Amps for 240 Volts The outlet is protected by a 30 Amp push to reset circuit breaker Use this plug to connect the unit to the Power Transfer System as described i...

Page 11: ...general reference Some electric motors such as induction types require about three times more watts of power for starting than for running This surge of power lasts for only a few seconds when startin...

Page 12: ...through cooling air slots some of the water will be retained in voids and cracks of the rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually de...

Page 13: ...6 Bad spark plug 7 Water in gasoline 8 Overchoking 9 Low oil level 10 Excessively rich fuel mixture 11 Intake valve stuck open or closed 12 Engine has lost compression 1 Set switch to Run 2 Clean or...

Page 14: ...Generac Portable Products 7200 Watt Mobile Backup Power System 14 SCHEMATIC...

Page 15: ...Generac Portable Products 7200 Watt Mobile Backup Power System 15 WIRING DIAGRAM...

Page 16: ...Generac Portable Products 7200 Watt Mobile Backup Power System 16 EXPLODED VIEW MAIN UNIT...

Page 17: ...6292 1 HHCS 10 Self Driller 38 77395 4 NUT Flange Lock M6 39 83465 4 GROMMET Tank 40 78831B 4 HHMS M6 1 0 x 60 SEMS 41 80270 1 VALVE Tank 42 78299 1 BUSHING Plastic Tank 43 B4363 1 CAP Fuel Gauge Item...

Page 18: ...50 5 HB4122 1 ASSEMBLY Handle Hitch 6 HB3375 1 WELDMENT Fork Pivot 7 HB4115 1 ASSEMBLY Pivot 8 B4134 1 GRIP Handle 9 B4135 1 PIN Handle Release Item Part Qty Description 10 89635 2 SPACER Wheel 11 222...

Page 19: ...BREAKER 30A Manual 2 Pole 13 23365 6 WASHER 8 Shakeproof 14 43437 1 OUTLET 120 240V 30A 15 43180 6 FLAT WASHER M4 16 22264 6 LOCK WASHER M4 Item Part Qty Description 17 51715 6 NUT M4 0 7 Hex 18 68759...

Page 20: ...al maintenance and service and does not apply to a generator set alternator or parts which have been subjected to improper or unauthorized installation or alteration misuse negligence accident overloa...