11
INSTRUCTION MANUAL
MEMORY FUNCTION
1. After turning the scale on, press the TARE button
to bring the display back to zero.
2. Place a scoop or item to be weighed onto the
weighing platform and when the displayed weight
of the item is stable, press the ON/MEM button
once. This will subtract the weight of the item
from the display and add the weight into the scales
memory (which is factory preset at zero). You will
notice an “M” on the scales display in the upper
right corner of the display that indicates there is
weight accumulated in its memory.
3. You may repeat this procedure as many times
as you like up until the cumulative weight in the
scales memory reaches 1000g.
4. To view the cumulative weight in the scales
memory, press the ON/MEM button again and it
will display the weight and the “M” will disappear
and the weight will then be subtracted from the
scales memory.
5. Press TARE button once in order to bring the
display back to zero and resume normal operation
of the scale.