background image

 

 
 
INTRODUCTION

 

The  SUPER  SCR

  series  are  designed  for  operation  with  1/3  to  1  1/2  HP  DC  brush-type  permanent  magnet  motors.    The 

compact  models are available in an economic chassis mount.  Models are available for 115 and 230VAC input.  Models 12M4-
00109 and 12M4-00110 have adjustable electronic current limiting that limits the maximum level of output current.   
 

Specifications:

 

 

Speed Range: 100:1 

 

Overload Capacity: 150% of rated current for 60 seconds 

 

Maximum Speed Adjustment: 50-110% of rated speed 

 

 

 

     Model             Input Voltage 

Output V. Range   

  HP  

 

Cont. Output Amps 

 

12M4-00109 

    115   

    0-90VDC 

 

3/4                               7.5 

 

12M4-00110 

    230   

    0-180  

 

1 1/2                            7.5 

 

 

 
GENERAL

 

These  instructions  provide  basic  information  for  installation  and  adjustment.    Please  contact  Gemini  Controls  LLC  if  further 
information  is  necessary.    It  is  possible  to  damage  the  drive  through  misuse  or  misapplication.    Please  read  this  material 
thoroughly before proceeding with installation.  
Unpack  the  equipment  noting  any  shortages  or  damaged  equipment.    Immediately  notify  the  carrier  of  any  damage.    Store  in 
clean, dry location if the product is not used immediately.  The relative humidity should not exceed 95%, non-condensing. 

 
 

INSTALLATION 

Carefully  mount  the  chassis    allowing  clearances  for  access,  air  flow  and  conduit  entry.    The  environment  should  be  free  of 
vibration  and  contaminants.    The  operating  temperature  range  for  the  Gemini  drive  is  32  to  104  degrees  Fahrenheit  (0-40C).  
Since the drive produces heat, utilize a source of cooling, such as a fan, when the ambient temperature approaches 104 degrees. 
 

    WARNING: 

Do not drill or file the enclosure or chassis when the controller is installed, as metal       

 

           

 

            particles can cause shorts and  damage. 

 

WIRING

 

 
1. Input Wiring - Connect the AC line to terminals “L1” and “L2” (note wiring diagram).    If the circuit is protected with a fuse 
or circuit breaker rated higher than 15 amps, fuse the “L1” connection path with a 15 amp fuse.  If required, the chassis may be 
grounded  at  one  of  the  unused  holes.    Input  wire  size  must  be  in  compliance  with  the  National  Electrical  Code  and  all  local 
codes and restrictions. 

 

WARNING

:

 Do not connect line power to the motor terminal connections. 

 
2. Output Wiring - Connect the negative and positive of the motor to the “A-” and “A+” terminals of the drive.  Do not operate 
the drive without connection to the motor. 
 
3. Control Wiring -  Connect a 10K, 1/4 watt speed potentiometer to the “L”, “W”, and “H” terminals, with the wiper connected 
to the “W” terminal.  If shielded wire is used, ground the shield at the potentiometer.  Never connect the shield at both ends.  Do 
not run control wiring in conduit with high voltage (120V or greater) wiring.

 

 

 

SUPER SCR INSTRUCTIONS

 

Models 12M04-00109 and 12M04-00110 

 

Reviews: