PAGE 04 - USER MANUAL
USER MANUAL - PAGE 05
2.6 - ALARM, INHIBIT TIME BETWEEN ALARMS AND ALARM CYCLES
2.7 - SYSTEM DISARMING
2.8 - EMERGENCY DISARMING BY ELECTRONIC KEY
A theft attempt
indicated
before another alarm starts, the system goes into “neutral time for
about ”5“ .
Press the unlock button on the original remote control of the vehicle.
System disarming is confirmed by two acoustic signals of the siren and two flashes of the turn
indicators.
P
als.
This disarming
is
by acoustic/optic signals.
After the alarm is triggered, but
An alarm event generates 10 alarm cycles of 30” each for each input and for each arming cycle.
An alarm condition is signalled by five acoustic signals and five flashes from the turn indicators.
aragraph 2.9 lists the various alarm causes and relative LED sign
mode is used for “EMERGENCY DISARMING” and “TOTAL DISARMING”.
Touching the electronic key to its receptable disarms and switches off the system which does not
rearm when the remote control is used.
To restore normal operation, touch electronic key to its receptacle.
A quick chirp and a flash of the status LED confirm that the system is back to normal
mode.
2.9 - ALARM MEMORY
Five flashes of the turn indicators and five acoustic signals upon disarming indicate a theft attempt.
The last cause of alarm can be identified by the LED memory.
Turn ignition key “ON” ; the vehicle status LED blinks according to the last alarm detected.
Optical signals are repeated 3 times; to interrupt, turn ignition key “OFF”.
The table below lists the various alarm causes and relative LED signals.
LED FLASHES
ALARM CAUSES
Nr. OF ALARM
CYCLES
10
10
10
10
Ignition attempt (+15/54)
Doors opening
Bonnet opening
Volumetric or external sensor
LED ON (1 second)
LED OFF (2 seconds)
3.0 - WARRANTY CONDITIONS
This product is guaranteed to be free from manufacturing defects for a period of 24 months from the
installation date shown on this warranty, in compliance with the Directive 1999/44/CE.
Please fill-in entirely the guarantee certificate included in this booklet and do NOT REMOVE the
guarantee label from the device.
The warranty will become void if labels are missing or torn, if the installation certificate is not fully
compiled or if the enclosed sale document is missing.
The guarantee is valid exclusively at authorized Gemini Technologies S.p.A. Service Centers.
The manufacturer declines any responsibility for eventual malfunctions of the device or any damage
to the vehicle electrical system due to improper installation, use or tampering.
This alarm system is solely intended to be a theft-deterrent device.
APPROPRIATE
CONTAINER ONLY
!
4.0 - WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT
(WEEE) DIRECTIVE
In the European Union, this label indicates that this product should not be disposed of with household
waste. It should be deposited at an appropriate facility to enable recovery and recycling (directive
2002/95/CE, 2002/96/CE and 2003/108/CE).
For information on how to recycle this product responsibly in your Country, please visit the web-site:
Www.eur-lex.europa.eu
5.0 - TECHNICAL SPECIFICATIONS
Power supply
Current absorption @ 12Vdc with system armed and LED flashing
Working range temperature
Turn signals relay contact capacity
Engine immobiliser relay contact capacity
Alarm cycle duration
Maximum positive current output when armed (+A)
Siren output current capacity
12 Vdc
From -30°C to +70°C
8 A at 20°C
30 sec.
15 mA
8 A at 20°C
700 mA
1 A