2.4.
Adding Salt
•
During the salt addition process, the system must be closed completely until all the salt is dissolved. If the
system is operated before the salt is completely dissolved, the cell may get irreversible damage. For this
reason, damage will result in the product being out of warranty.
•
Calculate the water volume of the pool, salt must be thrown so that there is a salt concentration of 5-6 kg
per cubic meter. During this process, make sure that the salt chlorine generator is not connected and do
not operate the filtration system for 24 hours.
•
In a newly coated pool, wait for 4 weeks after coating without adding salt.
•
The dissolution rate of salt can be accelerated for the pool cleaner. Make sure the salt concentration is 5-6
kg / m3 detailed.
•
The salt chlorine generator does not consume salt, but its concentration may decrease due to rain and
water supplements.
In cases where you need to add salt, pour the salt as close to the return line as possible.
Never pour into skimmers or suction strainers.
3
–
COMMISSIONING
–
USE
Check the electrical and plumbing again. Be sure to follow the assembly instructions written above correctly. If
there is no deficiency or error, you can start the commissioning process.
• Open the water inlet and water outlet valves,
turn off the bypass valve. Make sure there are no water
leaks in the valves and the chamber.
• Make sure that phase, neutral, and ground wires are properly connected. Remember, the device will work
with the pump and shut down with the pump. Open the residual current relay/fuse. Check the supply
terminals with the control pen or gauge.
• The control screen on the front of the device will be energized. There will be a closed mode screen on the
control screen.
• The generator will work at the factory settings
. If you want to change these settings, you can make the
necessary changes with the help of the user guide
3.1.Control Unit and Settings
1
- 2x7 Segment Display; information and warnings about the device
are displayed.
2
- LED Bar; Specifies the production percentage of cl and parameter
pages in the setting menu.
3
- Cl performs the functions of decreasing the production
percentage, switching to a sub-parameter in the setting menu, and
decreasing the parameter values.
4
- Cl performs the functions of increasing the production percentage,
switching to a higher parameter in the setting menu, and increasing
the parameter values.
5
- Device on / off (on / off) mode indicator LED
6
- Device full power operation mode indicator LED
7
- Selecting the parameters in the setup menu performs the
functions of confirming and saving the adjusted parameters.
8
- The device performs the functions of ON / OFF (switching on /
off), entering the setting menu (the device is turned off, pressed for 3
seconds when it is OFF), and output parameters from the setting
menu.