2.1.
Electrode Cell Assembly
1
- Electrode Cable Choke Seal
2
- Sleeve Electrode Head
3
- Cable Connection Terminals
4
- Electrode
5
- Silicone Gasket Between Electrode and Reservoir
6
- Electrode Chamber
7
- Water Inlet Connections Section
8
- Control Unit
9
- Water Outlet Connection Section
•
The device must be in a place with airflow, protected from rain, and without any water leakage hazard.
•
If there are acid tanks in the area where the device is located, there must be airflow in the environment.
Otherwise, electronic components may corrode with the effect of acid.
•
• The device
must be installed so that it is after the last element (filter, heater, etc.) through which water
enters the direction of return to the pool.
If an automatic pH regulator is installed in the system, the injection of the acid must be
after the electrode cell. Otherwise, the electrodes interact with acid and corrode. The
manufacturer and the seller cannot be held responsible for any damages and problems
caused by this reason. No repair, maintenance, or replacement parts can be requested
under the warranty.
•
Hard PVC adhesive must be used for pipe mounting to the electrode chamber and must be allowed to dry
completely before installing the electrode.
•
Electrode; it must be seated in the correct direction. The open part of the electrode must be inserted with
the water inlet pipe connection. Make sure the silicone gasket is in place and sealed tightly.
•
Connect the electrode cable through the cable choke seal and the threaded electrode head to the cable
connection terminals. Close the threaded electrode head.
•
It is recommended to install the three-valve bypass circuit as much as possible. In this way, it allows the
amount of water passing through the cell to be adjusted and the pool to work while it is removed from the
electrode chamber. The bypass circuit in the pump, which operates at a certain power, prevents the
electrodes from being damaged by vibration by decreasing the transition speed.
•
The electrode cell can be used in a vertical and horizontal position, but it is recommended to use it as
vertical as the environment allows. The vertical position allows the emptying of the chamber without
pouring water. Besides, enough space is provided to remove the electrode head and electrode.
•
If the cell is installed at a height below the filter outlet, gases produced by electrolysis can accumulate in
the chamber, which can damage the filtration elements. As seen in this picture, it can be prevented by
making a plumbing.