7
Chapter 4
Installation
This chapter provides information on how to install the SafeNet ProtectServer
Network HSM.
Since the SafeNet ProtectServer Network HSM is delivered with the necessary
software components pre-installed, no software installation is necessary on the unit
itself.
Once installation is complete, the unit can be tested to confirm correct operation and
to configure the network settings. These steps are covered in "Testing and
configuration" on page 9.
Installation procedure
To install the hardware
1.
Choose a suitable location to site the equipment. You can mount the SafeNet ProtectServer
Network HSM in a standard 19-inch rack, as described in the Quickstart Guide.
Note:
The plug in the power supply cord is the disconnect device for this equipment.
The equipment must therefore be installed near to the mains outlet socket to which
it is connected and the mains outlet socket must be easily accessible.
2.
Connect the SafeNet ProtectServer Network HSM to the network that hosts the client
machine(s) where the SafeNet cryptographic API software is installed. Connect the SafeNet
ProtectServer Network HSM to the network by inserting standard Ethernet cables into the LAN
connectors located on the front of the SafeNet ProtectServer Network HSM. The LAN connectors
are autosensing 10/100/1000 Mb/s Ethernet RJ45 ports.
Note:
The SafeNet ProtectServer Network HSM is equipped with two NICs (
eth0
and
eth1
), each of which can be configured with its own IP address. The NICs
incorporate an IPv4/IPv6 dual stack, allowing you to configure both an Ipv4 and
IPv6 address on each interface. If you intend to use both NICs, connect Ethernet
cables to both LAN connectors.
3.
Connect the power cable to the unit and a suitable power source. The SafeNet ProtectServer
Network HSM is equipped with an autosensing power supply that can accept 100-240V at 50-
60Hz.
Smart Card Reader Installation
The ProtectServer offers functionality supporting the use of smart cards. To make use
of these features, you must use a SafeNet-supplied smart card reader. Smart card
readers, other than those supplied by SafeNet, are not supported.
The SafeNet ProtectServer Network HSM supports two different card readers, as
follows:
the new USB card reader (introduced in 5.2)