2 SafeNet Luna Remote PED Installation and Configuration
Quantity
Item
Remote PED Setup
The Remote-Capable PED can be used either locally, connected directly to a SafeNet Luna HSM (exactly as for the
standard PED), or remotely when connected to a suitable workstation. The Remote PED must be connected to the
electrical main power supply.
The normal local use of a PED with Remote PED capability is to use it in Local mode to prepare an HSM. This is done
by imprinting an RPV (remote PED vector) onto the HSM and also onto an RPK (the orange Remote PED Key) before
shipping the HSM to its remote location. Then the PED can be switched to Remote PED mode, to serve any HSM that
has an appropriate RPV.
To configure the remote PED:
To use your HSM appliance and PED for local operation only, refer to the instructions in the
Configuration Guide
and the
HSM Administration Guide
.
To prepare an HSM for Remote PED operation, it needs a minimum of preparation as described in this section, below.
1.
From the software media (DVD or downloaded, un-tarred archive file), install the SafeNet Luna HSM Client
software onto the selected Windows computer that will act as the PED Server to your remotely located SafeNet
Luna HSM, ensuring that the Remote PED option is selected. Let the Windows "Found New Hardware" dialog
install it. The PedServer.exe and PedClient.exe applications are installed in SafeNet Luna HSM Client folder along
with any other SafeNet tools.
2.
For SafeNet Luna Network HSM, configure your HSM appliance for your network. Refer to the relevant
Configuration Guide
sections.
3.
Imprint the HSM with a Remote PED key (orange). Your must use a local connection for the first orange PED key
imprint.
a.
Connect the PED directly to the HSM that you will later be using remotely. Connect the PED to the power
supply.
SafeNet Luna Network HSM Installation Guide
Release 7.0 007-013576-002 Rev. A June 2017 Copyright 2001-2017 Gemalto All rights reserved.
28