2.2
Connecting the PLS62-W Evaluation Module to the DSB75
To properly connect the PLS62-W evaluation module and all accessories to the DSB75 please
complete the steps listed below. The complete setup with the evaluation module mounted onto
the DSB75 Adapter and the DSB75 Adapter connected to the DSB75 is shown in
.
•
Ensure that all jumpers and slide switches on the DSB75 are set to their default positions
as shown in
and in
.
•
Attach the 80-pin header of the DSB75 Adapter to the 2x40-pin connector (X101/X202)
located on the DSB75. Take gentle care that all pins are aligned correctly, then press down
evenly on the adapter until it is firmly seated.
•
Remove the knurled nuts from the DSB75 Adapter.
•
Mount the PLS62-W evaluation module onto the 80-pin board-to-board connector X120 of
the DSB75 Adapter.
•
Fasten the knurled nuts to secure the module to the DSB75 Adapter.
•
Use the small antenna cables to connect the U.FL GSM/UMTS/LTE main antenna connec-
tor and the U.FL UMTS/LTE Rx Diversity antenna connector on the PLS62-W evaluation
module to the U.FL-R SMT connectors on the DSB75 Adapter:
- for GSM/UMTS/LTE main antenna connect to X350
- for UMTS/LTE Rx Diversity antenna connect to X352
•
Screw the external antennas to the appropriate SMA connectors on the DSB75 Adapter:
- GSM/UMTS/LTE main antenna to X353
- UMTS/LTE Rx Diversity antenna connect to X351
•
Insert the SIM card into the card reader located at the DSB75 Adapter.
Note: Do not use the SIM card reader of the DSB75 Support Board.
•
To employ the module’s USB interface, plug the USB 2.0 Mini-B5 connector of the USB
cable to the Mini-B5 USB jack at the DSB75 Adapter. The other end of the USB cable con-
nects to a Windows PC.
Note: Do not use the USB connector located on the DSB75 Support Board.
•
To employ the module’s asynchronous serial interfaces ASC0 and/or ASC1, connect the 9-
pin SubD connectors on the DSB75 to the PC’s UART COM ports using the RS-232 cables.
Use COM1 (X201) for the first serial interface ASC0 and/or COM2 (X202) for second serial
interface ASC1.
•
Make sure that the power supply adapter delivers a minimum of 12 Volts, and connect the
power cables to the red (X400 = BATT+) and black (X401 = Ground) connectors of the
DSB75 Support Board.
After connecting the PLS62-W evaluation module to the DSB75, the module can be switched
on. The initial startup and possible USB driver installation are described in