Page 1: ... GEMALTO COM M2M Cinterion EMS31 US Hardware Interface Overview Version 00 103 DocId EMS31_US_HIO_v00 103 ...

Page 2: ...THE CONTEXT OF THE DELIV ERY OF THE PRODUCT THIS GENERAL NOTE SHALL BE GOVERNED AND CONSTRUED ACCORDING TO GERMAN LAW Copyright Transmittal reproduction dissemination and or editing of this document as well as utilization of its con tents and communication thereof to others without express authorization are prohibited Offenders will be held liable for payment of damages All rights created by paten...

Page 3: ... Interface 14 2 2 1 Antenna Installation 15 2 3 Sample Application 16 3 Operating Characteristics 18 3 1 Operating Modes 18 3 2 Power Supply 18 4 Mechanical Dimensions Mounting and Packaging 19 4 1 Mechanical Dimensions of EMS31 US 19 5 Regulatory and Type Approval Information 21 5 1 Directives and Standards 21 5 2 SAR requirements specific to portable mobiles 23 5 3 Reference Equipment for Type A...

Page 4: ...view of operating modes 18 Table 5 Directives 21 Table 6 Standards of North American type approval 21 Table 7 Standards of GCF and PTCRB type approval 21 Table 8 Requirements of quality 21 Table 9 Standards of the Ministry of Information Industry of the People s Republic of China 22 Table 10 Toxic or hazardous substances or elements with defined concentration limits 22 Table 11 Antenna gain limits...

Page 5: ...ial interface ASC0 9 Figure 3 Serial interface ASC1 10 Figure 4 External UICC SIM USIM card holder circuit 12 Figure 5 Schematic diagram of EMS31 US sample application 17 Figure 6 EMS31 US top and bottom view 19 Figure 7 Dimensions of EMS31 US all dimensions in mm 20 Figure 8 Dimensions of EMS31 US all dimensions in mm bottom view 20 Figure 9 Reference equipment for Type Approval 24 ...

Page 6: ...Notes as part of the technical docu mentation delivered with your Gemalto M2M product Feature Implementation General Frequency bands LTE Triband B2 B4 B12 Output power Class 3 23dBm 2dB for LTE 1900 LTE HD FDD B2 Class 3 23dBm 2dB for LTE AWS LTE HD FDD B4 Class 3 23dBm 2dB for LTE 700 LTE HD FDD B12 Power supply 3 2V to 5 5V Operating temperature board temperature Normal operation 30 C to 85 C Ex...

Page 7: ... lines 4 wire unbalanced asynchronous interface Default baud rate 115 200 baud Adjustable baud rates 1 200 to 3 686 400bps Supports RTS1 CTS1 hardware flow control UICC interface Supported SIM USIM cards 3V 1 8V Embedded UICC Module is hardware prepared for an embedded UICC MIM GPIO interface 20 pads of the application interface programmable as GPIO pads 17 or GPO pads 3 GP I Os can be configured ...

Page 8: ...I ADC and 2nd SIM MIM Second SIM MIM interface is hardware prepared only Figure 1 EMS31 US system overview GPIO interface I2C ASC0 CONTROL POWER ANTENNA LTEband Module SIM1 interface with SIM detection SIM1 Application BATT V180 VCORE Emergencyreset ON Serial modem interface I2C 4 4 1 1 1 Antenna 1 7 Status LED 1 FST_SHDN Fast shutdown 1 1 ADC ADC 1 COUNTER PWM 1 GP I Os SPI SPI 2 ASC1 Serial inte...

Page 9: ... 0V for low data bit or active state and 1 8V for high data bit or inactive state EMS31 US is designed for use as a DCE Based on the conventions for DCE DTE connections it communicates with the customer application DTE using the following signals Port TXD application sends data to the module s TXD0 signal line Port RXD application receives data from the module s RXD0 signal line Figure 2 Serial in...

Page 10: ...conventions for DCE DTE connections it communicates with the customer application DTE using the following signals Port TXD application sends data to module s TXD1 signal line Port RXD application receives data from the module s RXD1 signal line Figure 3 Serial interface ASC1 Features Includes only the data lines TXD1 and RXD1 plus RTS1 and CTS1 for hardware hand shake On ASC1 no RING line is avail...

Page 11: ... the model supplied by Molex which has been tested to operate with EMS31 US and is part of the Gemalto M2M reference equipment sub mitted for type approval See Section 7 1 for Molex ordering numbers Note No guarantee can be given nor any liability accepted if loss of data is encountered after removing the SIM card during operation Also no guarantee can be given for properly initializ ing any SIM c...

Page 12: ...e pads on EMS31 US and the pads of the external SIM card holder must not exceed 100mm in order to meet the specifications of 3GPP TS 51 010 1 and to satisfy the requirements of EMC compliance To avoid possible cross talk from the CCCLKx signal to the CCIOx signal be careful that both lines are not placed closely next to each other A useful approach is using a GND line to shield the CCIOx line from...

Page 13: ...he following features are not yet available with the current product release GPIO I2 C Pulse Counter PWM FST_SHDN and SPI After startup the above mentioned alternative GPIO line assignments can be configured using AT commands see 1 The configuration is non volatile and available after module restart Table 2 GPIO lines and possible alternative assignment GPIO Fast Shut down Status LED Pulse Counter...

Page 14: ...of 50Ω EMS31 US is capable of sustaining a 10 1 voltage standing wave ratio VSWR mismatch at the antenna line without any damage even when transmitting at maximum RF power The external antenna must be matched properly to achieve best performance regarding radi ated power modulation accuracy and harmonic suppression Antenna matching networks are not included on the EMS31 US module and should be pla...

Page 15: ...d with regard to the PCB s layer stack To prevent receiver desensitization due to interferences generated by fast transients like high speed clocks on the application PCB it is recommended to realize the antenna connection line using embedded Stripline rather than Microstrip line technology For type approval purposes an external application must connect the RF signal in one of the following ways V...

Page 16: ...est points for certain signals i e lines to and from the module for debug and or test purposes The SMT application should allow for an easy access to these signals For details on how to implement test points see 3 The EMC measures are best practice recommendations In fact an adequate EMC strategy for an individual application is very much determined by the overall layout and especially the po siti...

Page 17: ...IO I2 C Pulse Count er PWM FST_SHDN SPI ADC and 2nd SIM MIM Second SIM MIM interface is hardware prepared only Figure 5 Schematic diagram of EMS31 US sample application EMS31 US Antenna BATT GPIOs LED COUNTER PWMs I2CCLK I2CDAT GND V180 CCIN CCVCC CCIO CCRST CCCLK V180 CCIN2 CCVCC2 CCIO2 CCRST2 CCCLK2 ON FST_SHDN ASC0 ASC1 Power Supply 47µF 47µF 100pF 2k2 2k2 V180 µC 1nF 10pF 10pF 220nF SIM2 SIM1 ...

Page 18: ...ons No data transfer is in progress and no active communication via ASC0 ASC1 IDLE No data transfer is in progress The LTE part of the device can be in LTE DRX LTE eDRX or LTE PSM mode Activity on ASC0 ASC1 inter faces can be present Power consumption depends on the LTE power saving mode and its parameters and on the activity on the ASC inter faces Sleep The module is in low power consumption stat...

Page 19: ...kaging The following sections describe the mechanical dimensions of EMS31 US and give recommen dations for integrating EMS31 US into the host application 4 1 Mechanical Dimensions of EMS31 US Figure 6 shows the top and bottom view of EMS31 US and provides an overview of the board s mechanical dimensions For further details see Figure 7 Figure 6 EMS31 US top and bottom view Product label Top view B...

Page 20: ... Overview 4 1 Mechanical Dimensions of EMS31 US 20 EMS31_US_HIO_v00 103 2017 11 27 Confidential Preliminary Page 20 of 33 Figure 7 Dimensions of EMS31 US all dimensions in mm Figure 8 Dimensions of EMS31 US all dimensions in mm bottom view ...

Page 21: ...rtain hazardous substances in electrical and electronic equipment RoHS Table 6 Standards of North American type approval CFR Title 47 Code of Federal Regulations Part 22 and Part 24 Telecommunications PCS US Equipment Authorization FCC OET Bulletin 65 Edition 97 01 Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields UL 60 950 1 Product Safety Certi...

Page 22: ...64 2006 Marking for Control of Pollution Caused by Electronic Information Products 2006 06 According to the Chinese Administration on the Control of Pollution caused by Electronic Information Products ACPEIP the EPUP i e Environmental Protection Use Period of this product is 20 years as per the symbol shown here unless otherwise marked The EPUP is valid only as long as the product is operated with...

Page 23: ...r not further standards recommendations or directives are in force outside these areas Products intended for sale on US markets ES 59005 ANSI C95 1 Considerations for evaluation of human exposure to Electromagnetic Fields EMFs from Mobile Telecommunication Equipment MTE in the frequency range 30MHz 6GHz Please note that SAR requirements are specific only for portable devices and not for mobile dev...

Page 24: ...ttenuator is cho sen to connect the evaluation module directly to the LTE test equipment instead of employing the SMA antenna connectors on the EMS31 US DSB75 adapter as shown in Figure 9 The following products are recommended Hirose SMA Jack U FL Plug conversion adapter HRMJ U FLP 40 for details see see http www hirose connectors com or http www farnell com Aeroflex Weinschel Fixed Coaxial Attenu...

Page 25: ...ices where a separation distance between the antenna and any person of min 20cm can be assured during normal operating conditions For mobile and fixed operation configurations the antenna gain including cable loss must not exceed the limits in the following Table 11 for FCC and ISED IMPORTANT Manufacturers of portable applications incorporating EMS31 US modules are required to have their final pro...

Page 26: ...an for help Notes ISED EN This Class B digital apparatus complies with Canadian ICES 003 and RSS 210 Opera tion is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device FR Cet appareil numérique de classe B est conforme aux normes canadiennes ICES 003 et...

Page 27: ...document Cinterion EMS31 US Hardware Interface Description Version 00 101 New document Cinterion EMS31 US Hardware Interface Description Version 00 100 6 2 Related Documents 1 EMS31 US AT Command Set 2 EMS31 US Release Note 3 Application Note 48 SMT Module Integration 4 Universal Serial Bus Specification Revision 2 0 April 27 2000 6 3 Terms and Abbreviations Chapter What is new 5 4 Updated Table 1...

Page 28: ... Switched Data CTS Clear to Send DAC Digital to Analog Converter DAI Digital Audio Interface dBm0 Digital level 3 14dBm0 corresponds to full scale see ITU G 711 A law DCE Data Communication Equipment typically modems e g Gemalto M2M module DCS 1800 Digital Cellular System also referred to as PCN DNI Does not implemented DRX Discontinuous Reception DSB Development Support Box DSP Digital Signal Pro...

Page 29: ... International Telecommunications Union kbps kbits per second LED Light Emitting Diode Li Ion Li Lithium Ion Li battery Rechargeable Lithium Ion or Lithium Polymer battery LTE Long Term Evolution Mbps Mbits per second MIM Machine Identification Module MMI Man Machine Interface MO Mobile Originated MS Mobile Station GSM module also referred to as TE MSISDN Mobile Station International ISDN number M...

Page 30: ...pment RTS Request to Send Rx Receive Direction SAR Specific Absorption Rate SAW Surface Acoustic Wave SDIO Secure Digital Input Output SELV Safety Extra Low Voltage SIM Subscriber Identification Module SMD Surface Mount Device SMS Short Message Service SMT Surface Mount Technology SRAM Static Random Access Memory TA Terminal adapter e g GSM module TDMA Time Division Multiple Access TE Terminal Equ...

Page 31: ... suspension or denial of cellular services to the offender legal action or both Do not operate the cellular terminal or mobile in the presence of flammable gases or fumes Switch off the cellular terminal when you are near petrol stations fuel depots chemical plants or where blasting operations are in progress Operation of any elec trical equipment in potentially explosive atmospheres can constitut...

Page 32: ...apter R1 for mount ing EMS31 US evaluation modules onto DSB75 Gemalto M2M Ordering number L30960 N0010 A100 Approval adapter for mount ing EMS31 US evaluation modules onto DSB75 Gemalto M2M Ordering number L30960 N2301 A100 SIM card holder incl push button ejector and slide in tray Molex Ordering numbers 91228 91236 Sales contacts are listed in Table 13 Table 13 Molex sales contacts subject to cha...

Page 33: ...entity modules security solutions and licensing and monetization solutions to streamline development timelines and provide cost efficiencies that improve the bottom line As an experienced software provider we help customers manage connectivity security and quality of service for the long lifecycle of IoT solutions For more information please visit www gemalto com m2m www facebook com gemalto or Fo...