HOR. SIDEWALL & RECESSED HOR. SIDEWALL SPRINKLERS

UNIVERSAL MODEL A/Q-71

QUICK RESPONSE, 3 mm BULB TYPE, 5.6 K-FACTOR, 1/2" NPT**

GENERAL DESCRIPTION

The 5.6 K-Factor Quick Response Uni-
versal Model A/Q-71 Horizontal Side-
wall  and Recessed Horizontal Side-
wall Sprinklers (Ref. Figure A) are
automatic sprinklers of the “quick re-
sponse” frangible bulb type. They are
“standard  spray  sprinklers” intended
for use in fire sprinkler systems de-
signed in accordance with the stand-
ard installation rules recognized by the
applicable Listing or Approval agency
(e.g., UL Listing is based on NFPA 13
requirements).

Horizontal sidewall sprinklers are gen-
erally used in lieu of pendent and up-
right sprinklers because of building
construction or installation economy
considerations. They are designed for
installation along a wall or side of a
beam and just beneath a smooth ceil-
ing. Installed with their centerline of
waterway horizontal, these sprinklers
produce a quarter-spherical water dis-
charge pattern that is predominately
directed downward and outward from
the deflector; however, a portion of the
spray is also directed towards the back
wall.

The Model A/Q-71 Sprinklers feature a
unique “Deflector Hat” which provides
a low profile for improved aesthetics.

The recessed versions of the Model
A/Q-71 Sprinkler are obtained by util-
izing the Model A/Q-71  Sprinkler in
combination with either the Model
F700 or F705 Recessed Escutcheon
(Ref. Figures A and B). The F700 and
F705 Recessed Escutcheons have a
separable two-piece design which al-
lows installation of the sprinklers and
pressure testing of the fire protection
system, prior to wall construction
and/or application of a finish coat to
the wall. They also permit refinishing
of a wall surface without having to first
shut down the fire protection system
and remove the sprinklers.

The vertical adjustment  provided by
the F700 or F705 substantially re-
duces the accuracy to which the length
of fixed pipe nipples to the sprinklers
must be cut. Also, the Closure has a
1/2 inch (12,7 mm) wide flange which
provides ample clearance for covering
the mounting hole.

Lead coatings are utilized to extend
the life of copper alloy sprinklers be-
yond that which would otherwise be
obtained when exposed to corrosive
atmospheres. Although lead coated
sprinklers have passed the standard

corrosion tests of the applicable ap-
proval agencies, the testing is not rep-
resentative of all possible corrosive at-
mospheres.

Consequently,

it

is

recommended  that the end user be
consulted with respect to the suitability

Printed in U.S.A. 3-01

TD534

FIGURE A

5.6 K-FACTOR QUICK RESPONSE

MODEL A/Q-71 HORIZONTAL SIDEWALL (SIN G7378) SPRINKLERS

1 - Frame
2 - Button
3 - Gasketed
Spring
Plate
4 - Bulb
5 - Compression
Screw
6 - Deflector

*

Temperature rating is indicated on deflector or adjacent to orifice seat on frame.

**

Pipe thread connections per ISO 7/1 can be provided on special request.

2

4

5

PLATE SEATING

ESCUTCHEON

(11,1 mm)

NOMINAL

MAKE-IN

SURFACE

1

3

**

2-7/8" DIA.

ESCUTCHEON

F700 or F705

RECESSED

(73,0 mm)

WRENCH

FLATS

1-1/2"

(38,1 mm)

2-3/16"

(55,6 mm)

7/16"

1-13/16"

(46,0 mm)

MODEL

HAT

DEFLECTOR

1/2"

NPT

6

CENTERLINE

WATERWAY

OF SPRINKLER

*

9/16"

(14,3 mm)