background image

 
 

 
 

 

PRODUCT MANUAL 

Version 1.4 

 

 

PELLET BOILER STOVE – AMANDA Diva 16,1 kW

 

 

 

 

Page 1 

AMANDA 

diva

 

16,1kW

 

 

Carefully read all the instructions before the installation and use of the stove. 

This manual is an important part of the product. 

Address 

Gekas Metal Group - Gkekas Savvas & Yios OE Co 

Phone: +030 2310 538 103 | FAX: +030 2310 723 879 

17o hlm Thess/nikis - Veroias 

57003 Agios Athanasios, Thessaloniki, Greece 

[email protected]

 

www.gekasmetal.gr

 

Summary of Contents for AMANDA Diva

Page 1: ... the instructions before the installation and use of the stove This manual is an important part of the product Address Gekas Metal Group Gkekas Savvas Yios OE Co Phone 030 2310 538 103 FAX 030 2310 723 879 17o hlm Thess nikis Veroias 57003 Agios Athanasios Thessaloniki Greece info gekasmetal gr www gekasmetal gr ...

Page 2: ...dentification label 5 1 8 Delivery handling and packaging 5 1 9 Technical specifications 5 1 10 Electrical connection 5 2 Important information 6 2 1 General information 6 2 2 General warning and safety information 6 2 3 First heating 7 2 4 Safety distances 7 2 5 Before set up 7 2 6 The correct chimney connection 8 3 Brief information on pellets 9 3 1 What are pellets 9 3 2 Wood pellet specificati...

Page 3: ...splay brightness 20 8 3 Setting the beeper volume 21 8 4 Improving the combustion 21 9 Stove operation 22 9 1 Operating parameters 22 9 2 Switching the stove on 22 9 3 Modifying the parameters See 8 4 Improving the combustion 23 9 4 Switching the stove off 23 9 5 Operating by monitoring room temperature 23 9 6 Restarting after a power failure 23 10 Weekly Schedule 24 10 1 Weekly Timer 24 10 2 Sett...

Page 4: ...vents 1 4 MAIN REFERENCE STANDARDS EN ISO 9001 2015 Certificate of quality management system EN ISO 14001 2015 Certificate of environmental health and safety management system BS OHSAS 18001 2007 Certificate of occupational health and safety management system Directive 2014 35 UE Electrical equipment designed for use within certain voltage limits Directive 2014 30 UE Approximation of the laws of t...

Page 5: ...s center of gravity is towards the front of the appliance Always keep this in mind when moving the stove on the transport pallet When lifting avoid jolts or sudden movements Make sure that the forklift capacity exceeds the weight of the stove being lifted The operator of the forklift or hoisting equipment is responsible for lifting the loads To remove the stove from the transport pallet use approp...

Page 6: ...side walls Refrain from touching these parts without appropriate protective clothing or equipment e g heat resistant gloves or means of operation Make your children aware of this danger and keep them away from the stove during heating Only burn approved heating materials The combustion or introduction of highly flammable or explosive materials such as empty spray cans etc in the combustion chamber...

Page 7: ...ve a minimum distance of 40 cm behind and sideways the stove for maintenance 2 5 BEFORE SET UP Floor bearing capacity Ensure that the substructure can bear the weight of the stove prior to set up Note No modifications may be made to the firing installation This also leads to loss of warranty and guarantee Floor protection A base is recommended glass sheet steel or ceramic if the floor is combustib...

Page 8: ...ney please read the guide 5 Installing the stove or ask your local chimney sweep Wind and rain protection Wind and rain protection Wind and rain protection Insulated flue gas pipe Insulated flue gas pipe Insulated flue gas pipe Condensation proof T fitting with inspection plug Condensation proof T fitting with inspection plug Condensation proof T fitting with inspection plug 2m max distance and 3 ...

Page 9: ...te Only burn pellets that have been inspected according to ENplus A1 Using poor quality or prohibited pellet fuel will have a negative effect on the function of your pellet stove and can also lead to the warranty becoming null and void as well as the product liability connected with this Note Burning straw maize woodchips etc is not permitted Observe waste incineration legislation Non observance o...

Page 10: ...explosion There are rare cases where the stove fails to light the fire due to moisture in pellets dirty chimney dirty burning pot or bad pellet quality in that case the stove produces lot of smoke If the smoke cannot exit the stove freely through the flue gas pipe it will be accumulated in the combustion chamber This smoke is highly flammable which means that a spark will potentially ignite it cau...

Page 11: ... in the burn pot and the backlog reaches into the chute The feeder motor reacts in both cases with an increased current consumption The stove will be stopped In this case please call the service center immediately 4 12 POWER FAILURE DURING OPERATION After a brief power failure the operating functions that were set before the power failure continues If the power failure lasts longer the stove goes ...

Page 12: ... this context Note Only use heat resistant sealing materials as well as corresponding sealing strips heat resistant silicon and rock wool Note Also take care that the flue does not project into the free cross section of the chimney Note The stove should not be pushed on unprotected floors 5 3 CONNECTION TO THE CHIMNEY The device must be connected to an approved chimney for solid fuels The chimney ...

Page 13: ...nsure enough air intake the intake pipe should not exceed max 1m and have max 3 bends In extreme cold pay attention to icing on the air intake opening check It is also possible to suction in combustion air directly from another sufficiently vented room e g cellar The combustion air pipe must be tightly connected permanently to the air nozzles of the stove If you do not use the stove for a long tim...

Page 14: ...al service or a qualified technician to prevent any kind of risk The system must be earthed and fitted with a residual current circuit breaker in accordance with legislation in force Note The flue must have its own earth connection 5 10 2 INSTALLING THE AMBIENT ROOM THERMOSTAT The stove is equipped with a room thermostat cable located at the back of the stove untie the cable and place the thermost...

Page 15: ...until the trapped air in the boiler is fully removed Then screw the valve and close the side cover Repeat the process when the appliance is out of use for a long period of time See picture The appliance functions with an external thermostat which is activated in case of water overheating and cuts the power supply in order to turn the appliance off Manual deactivation unscrew the protective cover a...

Page 16: ...gram is used as an example and not as installation plan 1 Device 2 Circulator 3 Valve 4 Filter 5 Finishing valve 6 Radiator vent 7 Radiator body 8 Circulator thermostat 9 Thermometer 10 Manometer 11 Closed expansion tank 12 3 bar safety valve 13 Pressure relief valve Connection of pressure relief valve and 3 bar safety valve ...

Page 17: ... menus Two Edit buttons to modify the different values and parameters and access the submenus An Enter button to confirm the parameter or the settings Note All the buttons are capacitive which means you only need to firmly touch the buttons to use them No Fuel Alarm Cleaning Alarm Service Alarm IR Sensor Timer Indicator Setup menu Clock Menu Combustion Menu Water Temperature Menu Power Menu Edit B...

Page 18: ... can be modified using the Edit buttons The Cancel button is used to cancel any changes pressing and holding the button displays any active alarm or error codes 6 3 STATUS LEDS Icon Indication Description No Fuel Indicates that the pellet hopper needs to be refilled Cleaning Indicates the need to perform maintenance Service Indicates an error Remote control receiver It receives the inputs sent by ...

Page 19: ...the start end and temperature settings for each program Max 6 programs P1 to P6 4 Weekly timer days Assigns programs to the different days of the week Max 3 programs per day d1 to d7 Setup 1 Key lock Disables the buttons on the keypad OFF Lo Hi 2 Idle display brightness Sets the idle display brightness OFF 1 to 5 3 Idle display mode Sets the preferred display mode OFF 1 to 3 4 Beeper volume Sets t...

Page 20: ...ltage voltage spikes or other power related sources is excluded from warranty 8 INITIAL SETTINGS 8 1 TIME AND DATE SETTINGS To set the time date year and weekday a Use the buttons to go to the Clock menu b Use the buttons to scroll to and select submenu 1 and press to confirm c The hour value will start blinking use the buttons to modify the value and press d The minutes value will start blinking ...

Page 21: ...od combustion depends on several factors type of installation operation and maintenance conditions type of pellet etc If the brazier contains a lot of waste at the end of combustion it is advised to change the combustion configurations increasing the value to find the most satisfactory solution a Use the buttons to go to the Combustion menu and press b Use the buttons to set one of the following v...

Page 22: ...e of the desired temperatures is reached the stove will shut down In relation to the water temperature the stove shuts down at 2 C above the desired and turns on again at 2 C of desired In relation to the room temperature the setting comes directly from the room thermostat If the room thermostat is digital it allows for differential setting if it s analog the stove shuts down at the desired temper...

Page 23: ...Y MONITORING ROOM TEMPERATURE The stove can be switched on off manually or in programmed mode In relation to the water temperature the stove shuts down at 2 C above the desired and turns on again at 2 C of desired In relation to the room temperature the setting comes directly from the room thermostat If the room thermostat is digital it allows for differential setting if it s analog the stove shut...

Page 24: ...e buttons to modify the value and press g The off minute value will start blinking use the buttons to modify the value and press h The desired temperature value will start blinking use the buttons to modify the value and press i Press to confirm the settings 10 3 ASSIGNING THE WEEKLY TIMER PROGRAMS TO SPECIFIC DAYS This function can be used to assign up to three different programs to a certain day...

Page 25: ...Fri 16 C 18 C d6 Sat 15 C 18 C 17 C d7 Sun 15 C 18 C 19 C 11 MISCELLANEOUS SETTINGS 11 1 ENABLING KEY LOCK FUNCTION This function is used to disable the use of the control panel and avoid accidental modifications To enable disable the function a Use the arrow buttons to go to the Setup menu b Use the buttons to scroll and select submenu 1 and confirm by pressing c Use the buttons to set one of the...

Page 26: ...ses temperature warning level Chimney fire pot or heat exchanger cleaning required A004 Low battery Low battery A005 Speed sensor Speed sensor failure E002 IR communication error Infrared sensor malfunctioned E004 MB communication error Cable connecting motherboard to screen disconnected or malfunctioned E101 Fire error Error caused by 1 Ignition failed 2 Pellet quality 3 No pellets Chimney dirty ...

Page 27: ...garden it is a completely natural product The ash should be stored first and extinguished with water Note Ash may contain embers only place ash in sheet steel containers Warning Ensure that you do not vacuum into the combustion airline during heating operation during any cleaning vacuuming You could vacuum out embers FIRE RISK 13 1 INSPECTION AND MAINTENANCE PLAN Whenever started 7 days 1 month 1 ...

Page 28: ...aning Levers The window has to be cleaned from time to time Warning Blurred and dark colored glass is always a clue of poor combustion it is important to solve the problem before using the stove again 14 2 PROBLEM 2 Stove smells strongly and smokes outside Cause s Burning in phase service Stove has accumulated dust and or dirt Possible solutions Vacuum off any dust deposits from the convection air...

Page 29: ...s used only by individuals who have enough abilities and proper training Additionally the following must be provided Tax receipt showing the purchase date Installation protocol filled and signed by the installer see 16 Installation Protocol The warranty is NOT valid when the appliance has been misused due to incorrect operation by the user non professional modifications and or repairments or becau...

Page 30: ...nty documents Electrical periphery Connection socket earthed Functions checked Check of system component Combustion chamber door seal checked Exhaust line chimney Diameter Connection leakproof Total vertical part length m Chimney draught Total horizontal part length m Number of bends corners Hydraulic system Total amount of calories Installation type open closed Work performed correctly according ...

Page 31: ... all electrical equipment Separate the batteries fitted on the electronic boards Have the structure of the stove scrapped by an authorized company Important Dumping the stove in accessible areas represents a serious hazard to people and animals Liability for any harm cause to people or animals always lies with the owner When decommissioning the stove the CE mark this manual and other documents rel...

Page 32: ...ergy efficiency class A A A A Direct heat output kW 8 4 6 5 8 3 9 Indirect heat output kW 20 2 16 13 8 11 1 Energy efficiency index 101 1 97 95 7 97 3 Useful energy efficiency At nominal heat output 76 6 73 8 82 9 74 Unit Wood Burning Stoves Model SG 1200 SG 1100 MG 600 MG 500 Energy efficiency class A A A A Direct heat output kW 16 4 12 16 22 Energy efficiency index 107 7 91 5 108 103 1 Useful en...