Eng
lish
AGy -L
65
5 - Drive Keypad Operation
In this chapter the parameters management is described, by using the drive keypad.
5.1 Keypad
Changes made to parameter have immediate effect on drive operation, but are not automatically stored in
permanent memory. An explicit command is required to permanently store the parameters: "
C.000 Save
parameters
".
R
eset
Navigation
Hz
A
V
Prg
Rev
Fwd
Prg
E
R
eset
Navigation
Hz
A
V
Prg
Rev
Fwd
Prg
E
KBG-1 (standard)
KBG-LCD-.. (Optional)
Hz
A
V
Prg
Rev
Fwd
STARTUP
S000
Mains voltage
Parameter name
Menu
Parameter code
(Menu + number from 000 to 999)
Menu:
d
S
I
=DISPLAY
=STARTUP
=INTERFACE
F
P
A
C
=FREQ & RAMPS
=PARAMETER
=APPLICATION
=COMMAND
Hz
A
V
Prg
Rev
Fwd
S.000
Prg
Scroll menù:
Allows navigation thruogh the drive main menu (
d.xxx, S.xxx, I.xxx, F.xxx, P.xxx, A.xxx and
C.xxx
). Also used to exit the editing mode of a parameter without appling the changes.
E
Enter key:
Used to enter the editing mode of the selected parameter or to confirm the value.
UP key:
Used to scroll up through parameters or to increase numeric values while in editing mode; it can
also be used to increase motorpotentiometer reference value, when
F.000 Motorpot ref
parameter
is displayed (F, FREQ RAMP menu).
DOWN key:
Used to scroll down through parameters or to decrease numeric values while in editing mode; it can
also be used to decrease motorpotentiometer reference values, when
F.000 Motorpot ref
parameter
is displayed (F, FREQ RAMP menu).
I
Start key:
Used to
START
the drive via keypad; requirements:
+24V between 22 & 8 terminals (Enable)
+24 V between 23 & 8 terminals (Run Fwd) or + 24 V between 24 & 8 terminals (Run Rev)
P.000 Cmd source sel
= [
1] CtlWrd & kpd
parameter setting
O
Stop key:
Used to
STOP
the drive via keypad;
Keypad LED’s meaning:
PRG
(Yellow Led):
flashes if the parameters have not been permanently saved to memory.
REV
(Green Led):
reverse running (*)
Fwd
(Green Led):
forward running (*)
Hz, A, V
(Red Leds):
Indicates the unit of measurement of the parameter currently displayed (**).
Note:
(*)
Green LEDs blinking denote the action of the motor stall prevention.
(**)
Red LEDs blinking denote an active alarm condition.
Caution
Summary of Contents for SIEIDrive LIFT AGy -L
Page 1: ... Instruction manual SIEIDrive LIFT Lift vector AC Drives AGy L ...
Page 46: ...Italiano 46 AGy L ...
Page 90: ...English 90 AGy L ...
Page 134: ...Français 134 AGy L ...
Page 178: ...Deutsch 178 AGy L ...
Page 222: ...Español 222 AGy L ...
Page 240: ...NOTE ...
Page 241: ......