E-ABS
16
encoder connection, or 3.3, Second encoder connection (only from E revision).
The external power supply is normally used for the second encoder, because the drive power
pack is in a position to power supply just one encoder at the time.
Refer to the example diagrams in chapter 8, Use Examples.
The encoder external power supply must take into consideration the voltage drop along the
cable.
5. Jumpers
The following table describes the jumpers available on the card.
Name
Description
Default
S1
Reserved for future applications.
OFF=Reserved, ON=Reserved
OFF
teabs03g
6. Led
PWR ___________________________ Power supply voltage deriving from the regulation card; the procedu-
re leaves the reset status. This voltage can be measured by using a
specific device
.
7. Technical Data
Dimensions and weight
Dimensions ______________________
78,74 mm [3.1 inches] x 38,1 mm [1.5 inches]
Weight __________________________
23g [ 0.8 oz]