8
ADV200
WA • Functions description and parameters list
1 – MONITOR
The monitor menu displays the measured values of the sizes and of the drive operating parameters.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
1.1
250 Output current
A
FLOAT
16/32
0.0 0.0 0.0 R
VS
The drive output current is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
1.2
252 Output voltage
V
FLOAT
16/32
0.0 0.0 0.0 R
VS
The drive line voltage output is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
1.3
254 Output frequency
Hz
FLOAT
16/32
0 0 0 R
VS
The drive output frequency is displayed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
1.4
256 Output power
kW
FLOAT
16/32
0.0 0.0 0.0 R
VS
Displays the drive output power.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
1.5
628 Ramp setpoint
rpm
INT16
16/32
0 0 0 R
VS
The ramp reference is displayed. This is the speed value the drive must reach at the end of the ramp.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
1.6
664 Speed setpoint
rpm
INT16
16/32
0 0 0 R
VS
The speed reference is displayed. This is the value measured at the output of the speed reference circuit.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
1.7
260 Motor speed
rpm
INT16
16/32
0 0 0 R
VS
The actual output speed of the motor is displayed (in Flux vector OL/V/f control = speed estimated by the
drive).
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
1.8
270 DC link voltage
V
FLOAT
16/32
0.0 0.0 0.0 ER
VS
The direct voltage of the intermediate circuit capacitors is displayed (DC-Bus).
Summary of Contents for ADV200 WA
Page 84: ...84 ADV200 WA Functions description and parameters list 22 3 FUNCTIONS DC BRAKING ...
Page 274: ...274 ADV200 WA Block Diagrams G Block Diagrams System Diagrams Index Drive overview ...
Page 275: ...ADV200 WA Block Diagrams 275 References ...
Page 276: ...276 ADV200 WA Block Diagrams Ramps Multireference ...
Page 277: ...ADV200 WA Block Diagrams 277 Motorpotentiometer Jog function ...
Page 278: ...278 ADV200 WA Block Diagrams Monitor function ...
Page 279: ...ADV200 WA Block Diagrams 279 ...
Page 280: ...280 ADV200 WA Block Diagrams Commands ...
Page 281: ...ADV200 WA Block Diagrams 281 ...
Page 282: ...282 ADV200 WA Block Diagrams Digital inputs ...
Page 283: ...ADV200 WA Block Diagrams 283 Digital outputs ...
Page 284: ...284 ADV200 WA Block Diagrams Analog inputs ...
Page 285: ...ADV200 WA Block Diagrams 285 ...
Page 286: ...286 ADV200 WA Block Diagrams Analog outputs ...
Page 287: ...ADV200 WA Block Diagrams 287 Speed reg gains ...
Page 288: ...288 ADV200 WA Block Diagrams VF parameters ...
Page 289: ...ADV200 WA Block Diagrams 289 Functions ...
Page 290: ...290 ADV200 WA Block Diagrams ...
Page 291: ...ADV200 WA Block Diagrams 291 ...
Page 292: ...292 ADV200 WA Block Diagrams ...
Page 293: ...ADV200 WA Block Diagrams 293 Process ...
Page 294: ...294 ADV200 WA Block Diagrams ...
Page 295: ...ADV200 WA Block Diagrams 295 ...
Page 296: ...296 ADV200 WA Block Diagrams ...
Page 297: ...ADV200 WA Block Diagrams 297 ...
Page 298: ...298 ADV200 WA Block Diagrams ...
Page 299: ......