
136
ADV200
WA • Functions description and parameters list
3
Fbk1-Fbk2
4
Fbk1*Fbk2
5
Fbk1/Fbk2
6
Min fbk1fbk2
7
Max fbk1fbk2
8
Aver fbk1 fbk2
9
2 Zone min
10
2 Zone max
Set to
0
to select the value of feedback signal 1 as the feedback for the PID 1 function.
Set to
1
to select the value of feedback signal 2 as the feedback for the PID 1 function.
Set to
2
to select the result of the following formula as the feedback for the PID 1 function:
fbk1 value+(fbk2 value-50% Full scale)
Set to
3
to select the result of the following formula as the feedback for the PID 1 function:
(fbk1 value+50% Full scale)-fbk2 value)
Set to
4
to select the result of the following formula as the feedback for the PID 1 function:
(fbk1 value*(fbk2 value/50% Full scale)
Set to
5
to select the result of the following formula as the feedback for the PID 1 function:
(fbk1 value*50% Full scale) / fbk2 value)
Set to
6
to select the lower value between feedback 1 and feedback 2 as the feedback for the PID 1 function.
Set to
7
to select the higher value between feedback 1 and feedback 2 as the feedback for the PID 1 function.
Set to
8
to select the arithmetic mean of feedback 1 and feedback 2 as the feedback for the PID 1 function.
Set to
9
to calculate the differences between ref1-fbk1 and ref2-fbk2 and use the values equal to the smaller
difference for the PID 1 function.
Set to
10
to calculate the differences between ref1-fbk1 and ref2-fbk2 and use the values equal to the greater
difference for the PID 1 function.
Menu
PAR
Description
UM
Typo
FB BIT
Def
Min
Max
Acc
Mod
26.1.13 7336 PID 1 fbk filter
s
FLOAT
0.0 0.0 10.0
RW
VS
Setting of the value of the filter applied to the feedback signal.
Menu
PAR
Description
UM
Typo
FB BIT
Def
Min
Max
Acc
Mod
26.1.14 7326 PID 1 fbk out mon
PID1U
FLOAT
0.0 0.0 0.0 R
VS
The current value of the selected feedback is displayed.
Menu
PAR
Description
UM
Typo
FB BIT
Def
Min
Max
Acc
Mod
26.1.15 7330 PID 1 process unit
ENUM
%
0
39
RW VS
Use this parameter to select the unit of measure used in the process.
0
1
%
2
rpm
3
ppm
Summary of Contents for ADV200 WA
Page 84: ...84 ADV200 WA Functions description and parameters list 22 3 FUNCTIONS DC BRAKING ...
Page 274: ...274 ADV200 WA Block Diagrams G Block Diagrams System Diagrams Index Drive overview ...
Page 275: ...ADV200 WA Block Diagrams 275 References ...
Page 276: ...276 ADV200 WA Block Diagrams Ramps Multireference ...
Page 277: ...ADV200 WA Block Diagrams 277 Motorpotentiometer Jog function ...
Page 278: ...278 ADV200 WA Block Diagrams Monitor function ...
Page 279: ...ADV200 WA Block Diagrams 279 ...
Page 280: ...280 ADV200 WA Block Diagrams Commands ...
Page 281: ...ADV200 WA Block Diagrams 281 ...
Page 282: ...282 ADV200 WA Block Diagrams Digital inputs ...
Page 283: ...ADV200 WA Block Diagrams 283 Digital outputs ...
Page 284: ...284 ADV200 WA Block Diagrams Analog inputs ...
Page 285: ...ADV200 WA Block Diagrams 285 ...
Page 286: ...286 ADV200 WA Block Diagrams Analog outputs ...
Page 287: ...ADV200 WA Block Diagrams 287 Speed reg gains ...
Page 288: ...288 ADV200 WA Block Diagrams VF parameters ...
Page 289: ...ADV200 WA Block Diagrams 289 Functions ...
Page 290: ...290 ADV200 WA Block Diagrams ...
Page 291: ...ADV200 WA Block Diagrams 291 ...
Page 292: ...292 ADV200 WA Block Diagrams ...
Page 293: ...ADV200 WA Block Diagrams 293 Process ...
Page 294: ...294 ADV200 WA Block Diagrams ...
Page 295: ...ADV200 WA Block Diagrams 295 ...
Page 296: ...296 ADV200 WA Block Diagrams ...
Page 297: ...ADV200 WA Block Diagrams 297 ...
Page 298: ...298 ADV200 WA Block Diagrams ...
Page 299: ......