122
ADV200
WA • Functions description and parameters list
Not all alarms allow the controlled stopping of the drive. The following table shows the possibility of setting the Activi-
ties for the individual alarm signals.
Alarm
Ignore
Warning
Disable drive
Stop
Fast stop
ExtFlt
ü
ü
ü
ü
ü
Motor OT
ü
ü
ü
ü
ü
Overspeed
ü
ü
ü
ü
ü
SpdRefLoss
ü
ü
ü
ü
ü
SpdFbkLoss
ü
ü
ü
ü
ü
Drive ovld
ü
ü
ü
ü
ü
Motor ovld
ü
ü
ü
ü
ü
Bres ovld
ü
ü
ü
ü
ü
HTsens
-
-
ü
-
-
InAir
ü
ü
ü
ü
ü
Desat
-
-
ü
-
-
IOverC
-
-
ü
-
-
OverV
-
-
ü
-
-
UnderV
-
-
ü
-
-
PhLoss
ü
ü
ü
ü
ü
Bus option
ü
ü
ü
ü
ü
GroundFault thr
-
-
ü
-
-
Broken belt
ü
ü
ü
ü
ü
End curve
ü
ü
ü
ü
ü
Dry pump
ü
ü
ü
ü
ü
No flow
ü
ü
ü
ü
ü
Clean alarm
ü
ü
ü
ü
ü
Analog 1 Err
ü
ü
ü
ü
ü
Analog 2 Err
ü
ü
ü
ü
ü
Analog 1x Err
ü
ü
ü
ü
ü
Analog 2x Err
ü
ü
ü
ü
ü
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
24.1
4500 Fault reset src
LINK 16
1120
0
16384
RW VS
Selection of the origin (source) of the signal to be used for the command to reset the drive after an alarm. The
terminal that can be used for this function can be selected from among those listed in the “
L_DIGSEL2
” selec-
tion list.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
24.2
4502 ExtFlt src
LINK 16
6000
0
16384
RW VS
Selection of the origin (source) of the signal to be used as the input for the drive external fault alarm
ExtFlt
.
The terminal that can be used for this function can be selected from among those listed in the “
L_DIGSEL2
”
selection list.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
24.3
4504 ExtFlt activity
ENUM
Disable
0
4
RW VS
Setting of the behaviour of the drive in the event of an external fault alarm
ExtFlt
. This alarm indicates the
intervention of a drive external protection.
0
Ignore
1
Warning
2
Disable
3
Stop
4
Fast stop
Summary of Contents for ADV200 WA
Page 84: ...84 ADV200 WA Functions description and parameters list 22 3 FUNCTIONS DC BRAKING ...
Page 274: ...274 ADV200 WA Block Diagrams G Block Diagrams System Diagrams Index Drive overview ...
Page 275: ...ADV200 WA Block Diagrams 275 References ...
Page 276: ...276 ADV200 WA Block Diagrams Ramps Multireference ...
Page 277: ...ADV200 WA Block Diagrams 277 Motorpotentiometer Jog function ...
Page 278: ...278 ADV200 WA Block Diagrams Monitor function ...
Page 279: ...ADV200 WA Block Diagrams 279 ...
Page 280: ...280 ADV200 WA Block Diagrams Commands ...
Page 281: ...ADV200 WA Block Diagrams 281 ...
Page 282: ...282 ADV200 WA Block Diagrams Digital inputs ...
Page 283: ...ADV200 WA Block Diagrams 283 Digital outputs ...
Page 284: ...284 ADV200 WA Block Diagrams Analog inputs ...
Page 285: ...ADV200 WA Block Diagrams 285 ...
Page 286: ...286 ADV200 WA Block Diagrams Analog outputs ...
Page 287: ...ADV200 WA Block Diagrams 287 Speed reg gains ...
Page 288: ...288 ADV200 WA Block Diagrams VF parameters ...
Page 289: ...ADV200 WA Block Diagrams 289 Functions ...
Page 290: ...290 ADV200 WA Block Diagrams ...
Page 291: ...ADV200 WA Block Diagrams 291 ...
Page 292: ...292 ADV200 WA Block Diagrams ...
Page 293: ...ADV200 WA Block Diagrams 293 Process ...
Page 294: ...294 ADV200 WA Block Diagrams ...
Page 295: ...ADV200 WA Block Diagrams 295 ...
Page 296: ...296 ADV200 WA Block Diagrams ...
Page 297: ...ADV200 WA Block Diagrams 297 ...
Page 298: ...298 ADV200 WA Block Diagrams ...
Page 299: ......