Table 2.3.4.1: Nominal Drive Current
1007
1015
1022
1030
2040
2055
2075
31
10
3150
4220
4300
4370
5450
5550
6750
7900
71
100
71320
81600
Continuous
service,
no
overload
(IEC
146
class
1
)
[A]
2.4
4
5.6
7
.5
9.6
12.6
17.7
24.8
3
3
4
7
6
3
7
9
9
3
1
14
142
185
210
250
324
Overload
service
150%x60s
followed
b
y
In,m
in
.c
y
cle
time
360s
(IEC
146
class2)
[A]
2.2
3
.6
5.1
6
.8
8.7
1
1.5
16.1
22.5
29.9
42.6
57.1
71.6
84.3
103.4
128.7
167.7
190.4
227
293.8
Overload
service
200%x10s
followed
b
y
In,m
in
.c
y
cle
time
30s
[A]
1.6
2
.7
3.8
5
.1
6.5
8
.6
12.0
16.9
22.4
3
2
42.8
53.7
63.2
77.5
96.6
125.8
142.8
170
220.3
Overload
service
200%x60s
followed
b
y
In,m
in
.c
y
cle
time
160s
[A]
1.6
2
.7
3.8
5
.1
6.5
8
.6
12.0
16.9
22.4
3
2
42.8
53.7
63.2
77.5
96.6
125.8
142.8
170
220.3
Overload
service
250%x10s
followed
b
y
In,m
in
.c
y
cle
time
25s
[A]
1.3
2
.2
3.0
4
.1
5.2
6
.8
9.6
13.5
1
8
25.6
34.3
4
3
50.6
6
2
77.2
100.6
1
14.2
136
176.3
Overload
service
300%x10s
followed
b
y
In,m
in
.c
y
cle
time
25s
[A]
1.1
1
.8
2.5
3
.4
4.3
5
.7
8.0
1
1.2
1
5
1
6
21.4
2
7
31.6
38.8
48.3
6
3
71.4
8
5
1
10.2
Overload
service
300%x60s
followed
b
y
In
,
m
in.c
y
cle
time
130s
[A]
1.1
1
.8
2.5
3
.4
4.3
5
.7
8.0
1
1.2
1
5
1
6
21.4
2
7
31.6
38.8
48.3
6
3
71.4
8
5
1
10.2
Continuous
service,
no
overload
(IEC
146
class
1
)
[A]
2.1
3
.5
4.9
6
.5
8.3
1
1
15.4
21.6
28.7
4
0
5
4
6
8
8
1
9
9
124
160
183
217
282
Overload
service
150%x60s
followed
b
y
I
n
,m
in
.c
y
cle
time
360s
(IEC
146
class2)
[A]
1
.9
3.2
4
.4
5.9
7
.6
10
14
19.6
2
6
36.3
4
9
61.7
73.4
89.8
1
12.4
145.1
166
196.7
255.7
Overload
service
200%x10s
followed
b
y
I
n
,m
in
.c
y
cle
time
30s
[A]
1
.4
2.4
3
.3
4.4
5
.6
7.5
10.5
14.7
19.5
27.2
36.7
46.2
55.1
67.3
84.3
108.8
124.4
147.6
191.8
Overload
service
200%x60s
followed
b
y
I
n
,m
in
.c
y
cle
time
160s
[A]
1
.4
2.4
3
.3
4.4
5
.6
7.5
10.5
14.7
19.5
27.2
36.7
46.2
55.1
67.3
84.3
108.8
124.4
147.6
191.8
Overload
service
250%x10s
followed
b
y
I
n
,m
in
.c
y
cle
time
25s
[A]
1
.1
1.9
2
.7
3.5
4
.5
6.0
8
.4
1
1
.7
15.6
21.8
29.4
3
7
4
4
5
4
67.5
8
7
99.6
1
18
153.4
Overload
service
300%x10s
followed
b
y
I
n
,m
in
.c
y
cle
time
25s
[A]
0
.9
1.6
2
.2
2.9
3
.8
5.0
7
.0
9.8
1
3
13.6
18.4
23.1
27.5
33.7
42.2
54.4
62.2
73.8
95.9
Overload
service
300%x60s
followed
b
y
I
n
,m
in
.c
y
cle
time
130s
[A]
0
.9
1.6
2
.2
2.9
3
.8
5.0
7
.0
9.8
1
3
13.6
18.4
23.1
27.5
33.7
42.2
54.4
62.2
73.8
95.9
2002
2003
2005
3007
3010
3015
3020
4025
4030
4040
5050
5060
5075
6100
7125
7150
8200
Continuous
service,
no
overload
(IEC
146
class
1
)
[A]
3.8
4
.5
7.0
10.8
13.8
18.7
24.2
3
0
3
6
4
6
5
8
6
9
8
6
109
137
158
21
1
Overload
service
150%
x
60s
followed
b
y
In,
m
in.c
y
cle
time
360s
(IEC
146
class2)
[A]
3.5
4
.1
6.4
9
.8
12.6
17.0
22.0
2
7
3
3
4
2
5
3
6
3
7
8
99.2
124.7
144
192
Overload
service
200%
x
10s
followed
b
y
In,
m
in.c
y
cle
time
30s
[A]
2.6
3
.1
4.8
7
.4
9.5
12.8
16.5
20.3
24.8
31.5
39.8
47.3
58.5
74.1
93.2
107.4
143.5
Overload
service
200%
x
60s
followed
b
y
In,
m
in.c
y
cle
time
160s
[A]
2.6
3
.1
4.8
7
.4
9.5
12.8
16.5
20.3
24.8
31.5
39.8
47.3
58.5
74.1
93.2
107.4
143.5
Overload
service
250%
x
10s
followed
b
y
In,
m
in.c
y
cle
time
25s
[A]
2.1
2
.5
3.8
5
.9
7.6
10.2
13.2
16.2
19.8
25.2
31.8
37.8
46.8
59.3
74.6
85.9
1
14.8
Overload
service
300%
x
10s
followed
b
y
In,
m
in.c
y
cle
time
25s
[A]
1.8
2
.1
3.2
4
.9
6.3
8
.5
1
1
.0
13.5
16.5
21.0
26.5
31.5
39.0
49.4
62.1
71.6
95.6
Overload
service
300%
x
60s
followed
b
y
In,
m
in.c
y
cle
time
130s
[A]
1.8
2
.1
3.2
4
.9
6.3
8
.5
1
1
.0
13.5
16.5
21.0
26.5
31.5
39.0
49.4
62.1
71.6
95.6
av
y
2020
-I
2N
Rated
output
current
(@
U
LN
=230-400V
ac)
:
-I
2N
xK
V
Rated
output
current
(@
U
LN
=460/480V
ac)
:
A
V
y-…-4
(230…480V
ac)
-I
2N
xK
V
Rated
output
current
(@
U
LN
=575V
ac)
:
A
V
y-…-5
(575V
ac)
Summary of Contents for ARTDrive Vector V2 400Vac Series
Page 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Page 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...