TORQUE / Torque zero command
N
OTE
!
Menu accessible with Access Level = FULL
The block controls the Zero Torque sets the sum of Speed regulator Torque
reference to zero. (Torque reference is referred to Torque ref 1, Torque ref 2 and Torque
ref 3).
The origin of the zero Torque command signal can be selected via the “Zero trq cmd src”
source.
The parameters and the sources included into “Torque” are available only with a
Sensorless and Field Oriented mode.
G03 TORQUE / Trq 0 cmd
G04.00 Zero torque src
N/A
RWS
Ipa4000
PList 3
PIN
F-S-B
Full
2451
Ipa 4000 - NULL= Default
It select the origin of the signal of Torque zero command.
ª
ª
ª
ª
ª
Pick List 3
G04.01 Zero torque mon
N/A
R
0
0/1
DV
F-S-B
Full
2452
It displays of the Torque zero command state:
0 = not active
1 = active
Summary of Contents for ARTDrive Vector V2 400Vac Series
Page 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Page 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Page 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Page 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Page 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Page 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...