ARTDrive V2 series - Instruction Manual
Chapter 6 Parameter • 109
B STARTUP
The drive can control the motor in three different ways: V/f (VF), Field Oriented (FOC)
and Sensorless vect (SLS).
Start the process for the motor data automatic measuring.
•
Automatic calculation of the flux and current loop gains according to the performed
measuring processes.
•
Setting of the information about:
- maximum speed
- configuration of the V/f mode.
- drive parameters (mains voltage, ambient temperature, etc.)
- motor parameters
- inverter main commands
- inverter main reference
- motor/inverter ramp times
- encoder features, if used.
- parameters of the I2t protections.
Such settings can be changed only with a disabled drive. While in this operation mode
(Configuration) the data updating on the terminal strip and on the option cards is stopped.
B00 STARTUP / Drv & Mot config
After downloading drive parameters from a file, or entering the
STARTUP / Drv & Mot
config
menu through the keypad, the drive restart is only permitted after:
a)
cycling drive power
or:
b)
when
Commands
select =
Terminal level,
cycling input DI0,
when
Commands
select =
Terminal edge
, cycling input DI0, and the digital input
selected by
Term strstp src
,
when
Commands
select =
Digital level
, cycling the digital signals selected by
Digital strstp src
and
Digital enable src
when commands select =
Digital edge
, cycle input DI0 or the digital input
Digital
enable src
(if not selected to ONE), and the digital signal selected by
Digital
strstp src
.
It allows to select the desired regulation mode. After choosing the setting, the Drive
carries out the restart phase by setting the selected regulation mode.
B0A STARTUP / Drv & Mot config / Regulation mode
B0A.00 Regulation mode
N/A
R
0
0/7
DK
V-F-S
Easy 100
It allows to select the desired regulation mode. When the
Regulation mode
parameter is
selected, the active regulation mode is displayed; in order to change it to a new mode
press “Enter”; then scroll the list:
[1] V/f control
V/f scalar control
[2] FOC control
Field Oriented control
[3] SLS control
Sensorless control
Summary of Contents for ARTDrive Vector V2 400Vac Series
Page 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Page 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Page 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Page 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Page 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Page 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...