34
RS-232 SERIAL CONTROL
#LIST Function
The #LIST function displays the list of all the available functions that can be
executed on the serial port. It also gives the number of parameters that each
function requires.
Syntax:
#LIST
Parameters:
None
#MOTIONTHRES Function
The #MOTIONTHRES function sets the intraframe motion detection threshold
for the deinterlacer on the VXP processor. Video artifacts can be created when
de-interlacing (creating interlaced
fi
elds from progressive
fi
elds). This function
allows adjustment of the threshold used by the de-interlacer motion detection
algorithm, removing / minimizing motion artifacts in the converted video.
Syntax:
#
MOTIONTHRES
param1
Parameters:
param1
Value
[0
-
15]
Notes:
The default value is 4.