HG1
26 / 26
Version 0 • Dokument-Nr. 74572811
Internet: www.gefa.com • E-Mail: [email protected]
10.1.1 Mounting of the hand lever
Follow the instructions below when assembling the hand lever:
>
Screw the stud bolt (3.2) into the body and put the washer (3.8) on it.
>
Insert the clamping bolt(3.4) into the hand lever (3.1) in such a way that the slit in the clamping bolt is
aligned with the square in the hand lever..
>
Place the hand lever on the shaft. The hand lever must lie on top of the washer(3.8).
>
Tighten the clamping bolt with nut(3.7), thus fixing the hand lever to the shaft.
>
Close the valve and adjust the stop position using the screw (3.5) einstellen. Secure the screw with a
nut(3.6).
>
Screw the star knob(3.3) onto the stud bolt. For operating the valve loosen the star knob and retighten after-
wards.
10.1.2 Mounting of the MULTITOP mounting plate
Follow the instructions below when assembling the MULTITOP mounting plate:
>
Place the mounting plate (2.1) on the body.
>
Insert the spring dowel sleeves (2.2) through the mounting plate into the body. The slit in the split taper
sleeve must be facing in the force direction (see arrow in the mounting drawing) to reach a rigid connection.
>
Do notinsert the mounting plate without using spring dowel sleeves as the transverse forces cannot be
taken on by the screws.
>
Insert the cylinder screws (2.3) and tighten them.
>
If required, push the square adapter (2.5) onto the shaft. If necessary, use the enclosed retaining ring to en-
sure that the square adapter will not slip off the shaft (2.4).